K3HB-RNB 100-240VAC Omron, K3HB-RNB 100-240VAC Datasheet - Page 8

ROTARY PULSE INDICATR NPN/V INPT

K3HB-RNB 100-240VAC

Manufacturer Part Number
K3HB-RNB 100-240VAC
Description
ROTARY PULSE INDICATR NPN/V INPT
Manufacturer
Omron
Series
K3HBr
Type
Pulse Meterr
Datasheet

Specifications of K3HB-RNB 100-240VAC

Measuring Range
0 ~ 50kHz
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-RNB100-240VAC
K3HBRNB100240VAC
8
F2
Absolute
ratio
F3
Error ratio
F4
Rotational
difference
F5
Flow rate
ratio
F6
Passing
time
Function
Multiples input B divided by input A ( ) by 100 and
displays the ratio as a percentage (%).
Multiplies the error between input A and input B
(
(%).
Displays the difference between input A and input B
(B - A) as the rotation (rpm) speed error or
circumferential speed error.
æ
ç
ç
ç
ç
è
Displays the flow rate ratio of B from inputs A and B
(
Passing time (s) = 1/ƒa
ƒa: Input frequency (Hz)
Set the prescale value for the desired display unit using
the following table for reference.
N = Pulses per rotation
L = Length of process (m)
Rotary Pulse Indicator
B
A
A+B
Passing time
d = Circumferential length per rotation (m)
Display unit: %
Display unit: %
Display unit:
Display unit: %
B
Calculation
rpm, rps, rph,
Hz, kHz, mm/s, m/s
m/min, km/h
l/min, l/h, etc.
1) by 100 and displays the ratio as a percentage
) as a ratio (%).
Display unit Prescale value ( )
Operation
ö
÷
÷
÷
÷
ø
s
K3HB-R
B
A
L/( d/N)
Measuring the speed ratio between two rollers
Measuring the line speed error ratio between two conveyors
Measuring the rotation (rpm)/circumferential speed error (absolute error)
between two conveyors
Monitoring liquid mixture flow rate ratio
Displaying the passing time for a conveyor line
Operation image (application)
Distance
Linear output
Communications
output
(remote monitoring)
Recording meter
Warning
output
H
PASS
L
Warning
Warning
HH
H
PASS
L
LL
HH
H
PASS
L
LL
To computer