PAXLID00 Red Lion Controls, PAXLID00 Datasheet

METER DC CURRENT 3 1/2-DIGIT

PAXLID00

Manufacturer Part Number
PAXLID00
Description
METER DC CURRENT 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Ammeterr
Datasheet

Specifications of PAXLID00

Measuring Range
0 ~ 199.9mA
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115VAC,230 VAC
No. Of Digits / Alpha
3-1/2
Meter Function
DC Ammeter
Meter Range
199.9uA To 1.999A
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
115V
Accuracy
±0.1% (199.9 µA to 19.99 mA)
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.1 μA to 1 mA
Function
Ammeter
Meter Type
DC Current
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
199.9 μADC to 1.999 ADC
Special Features
Multi-Range Unit
Standards
cULus Listed, CE Marked
Temperature, Operating
0 to 60 °C
Time, Response
1 Second nominal
Voltage, Supply
115/230 VAC
Weight
0.65 lbs
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
RLC105
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL PAXLI - PAX LITE CURRENT METERS &
MODEL PAXLV - PAX LITE VOLTMETERS
GENERAL DESCRIPTION
for tough industrial applications. With multi-range capability, built-in provision
for scaling, and DIP switch selectable decimal points, these meters offer the
ultimate in application flexibility. Four models cover your voltage and current
indicator needs. The meter can provide direct readout from pressure, speed or
flow transducers, or any other variable that can be translated to voltage or
current. The built-in scaling allows the display to be scaled to the desired
engineering unit.
is negative) features a 0.56" high, 7-segment LEDs for easy reading. The meter
is also available with custom units label capability. Using the PAX label kit
(PAXLBK30), the selected label is installed behind the panel, keeping it safe
from washdown or other environmental conditions. A DIP switch is used to
control the backlight for the units label.
noise effects to CE requirements, allowing the meter to provide a tough yet
reliable application solution.
C C
DIMENSIONS In inches (mm)
PAX Lite Current and Volt Meters are premium quality instruments designed
The 3 ½ -digit bi-polar display (minus sign displayed when current or voltage
The meters have a NEMA 4X/IP65 sealed bezel and extensive testing of
installation and operation of the unit.
Read complete instructions prior to
U L
CAUTION: Risk of Danger.
R
US LISTED
US LISTED
(96.5)
3.80
IND. CONT. EQ.
51EB
(49.5)
1.95
CAUTION: Risk of electric shock.
(2.5)
.10
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is
2.1" (53.4) H x 5.0" (127) W.
(104.1)
4.10
1
*
SAFETY SUMMARY
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
DEFINITION OF TERMS
199.9
1.999 V to 300 V (AC or DC)
Accessory Shunts Available For Higher Current Ranges.
FOUR MULTI-RANGE UNITS COVER:
3 1/2-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAY W/POLARITY
BUILT-IN SCALING PROVISIONS
SELECTABLE DECIMAL POINT LOCATION
AUTO ZEROING CIRCUITS
OVER-RANGE INDICATION
NEMA 4X/IP65 SEALED FRONT BEZEL
OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT
All safety related regulations, local codes and instructions that appear in the
INSTALLATION CATEGORY (overvoltage category) I, (CAT I):
INSTALLATION CATEGORY (overvoltage category) II, (CAT II):
Signal level, special equipment or parts of equipment, telecommunication,
electronic, etc. with smaller transient overvoltages than Installation
Category (overvoltage category) II. (See IEC 664 & IEC 61010)
Local level, appliances, portable equipment, etc. with smaller transient
overvoltages than Installation Category (overvoltage category) III. (See
IEC 664 & IEC 61010)
A to 1.999 A *, 199.9 mV (AC or DC)
(44.5)
1.75
1 2 3 4
5 6
3.60 (91.4)
7
8 9 10 11
Bulletin No. PAXLI/V-E
Drawing No. LP0566
Released 10/10
(44.5)
1.75

PAXLID00 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLI - PAX LITE CURRENT METERS & MODEL PAXLV - PAX LITE VOLTMETERS LISTED US LISTED R IND. CONT. EQ. 51EB GENERAL DESCRIPTION PAX Lite ...

Page 2

ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications . . . . . . . . ...

Page 3

G M ENERAL ETER 1. DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment red LED, (-) minus sign displayed when current or voltage is negative. Decimal points inserted before 1st, 2nd, or 3rd least significant digits by DIP switch selection. ...

Page 4

I NSTALLING THE Installation The PAX meets NEMA 4X/IP65 requirements when properly installed. The unit is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the unit. ...

Page 5

PAXLV Jumper Selection FRONT DISPLAY Main Circuit Board SET-UP DIP SWITCHES SCALING POT POWER SELECTION SWITCH INPUT RANGE JUMPER REAR TERMINALS 3.0 W IRING THE WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the ...

Page 6

POWER WIRING AC Power Terminal 1: VAC Terminal 2: VAC 1 2 115/230 4.0 S CALING THE PAXLV DIRECT VOLTMETER READOUT When the application requires direct voltmeter readout, the Scale Switch should remain in the “OFF” position. The Input ...

Page 7

PAXLI DIRECT CURRENT METER READOUT When the application requires direct current meter readout, the Scale Switch should remain in the “OFF” position. The Input Range Jumper is set to the current range being applied possible to select a ...

Page 8

... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...