DMS-20PC-0-RS-C Murata Power Solutions Inc, DMS-20PC-0-RS-C Datasheet
DMS-20PC-0-RS-C
Specifications of DMS-20PC-0-RS-C
Available stocks
DMS-20PC-0-RS-C Summary of contents
Page 1
... A DISPLAY ENABLE function permits the display to be disabled for "power-down" operation. All models have a DISPLAY TEST function. Standard red LED models offer an optional DISPLAY HOLD function. Small size, low cost and adjustment-free reliability make the DMS-20PC Series the best choice for all your 3½ digit, LED, DPM applications. +5V V+ – ...
Page 2
... Model Applied "0" Voltage Load Current* DMS-20PC-X-XL +0.05V max. All Others +0.4V max. * The driving gates must be able to sink this much current email: sales@murata-ps.com 15 Feb 2010 MPM_DMS_20PC.D06 Page 0.7mA max. 6mA max. ...
Page 3
... RETURN). 1. Single-Ended Input Confi gurations: True single-ended measure- ments can be made with any DMS-20PC meter. The circuit of Figure 2 avoids problems normally associated with ground-loop currents. Separate ground runs should be used for 5V RETURN (pin 3) and (–) INPUT LO (pin 12) ...
Page 4
... APPLICATIONS 2. Differential Input Confi gurations: Differential measurements can be made with all DMS-20PC meters. Figure 3, though not a practical real-world application, uses a voltage divider to demonstrate the concept of a differential input signal. Be care- ful not to exceed the ±2V common mode voltage limitation for 5V-powered meters ...
Page 5
... The low-power, red LED DMS-20PC-2-RL can be confi gured to allow power supply monitoring over the range of 4.5-18Vdc. The circuit in Figure 8 uses a low-drop-out, three-ter- minal regulator (LM-2931Z-5, available from National Semicon- ductor) to provide regulated 5V-power to the meter ...
Page 6
... DP2 DP3 1.38 (35.1) 1.30 (33.0) 0.475 (12.07) 0.040 (1.02) 0.25 (6.4) TYP. 0.10 1.10 0.10 (2.5) (27.9) (2.5) TYP. TYP. 0.040 (1.02) ® ® ® ® BEZEL email: sales@murata-ps.com 15 Feb 2010 MPM_DMS_20PC.D06 Page PANEL © 2010 Murata Power Solutions, Inc. ...