H7CX-AWSD DC12-24 Omron, H7CX-AWSD DC12-24 Datasheet - Page 29

COUNTER SCREW-TERM 6DIGT 1/16DIN

H7CX-AWSD DC12-24

Manufacturer Part Number
H7CX-AWSD DC12-24
Description
COUNTER SCREW-TERM 6DIGT 1/16DIN
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-AWSD DC12-24

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
12 V ~ 24 V
Display Type
*
No. Of Digits / Alpha
6
Signal Input Type
PNP/NPN
Supply Voltage Max
24V
Panel Cutout Height
48mm
Supply Voltage Min
12V
Panel Cutout Width
48mm
Connector Type
Screw Terminal
Counter Supply Voltage
12-24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AWSDDC12-24
H7CXAWSDDC1224
Reset Function List
Self-diagnostic Function
The following displays will appear if an error occurs.
Note: 1. The display for 4-digit models is given in parentheses.
Function
Screen dis-
played in run
mode
Reset/reset 1
Total reset/re-
set 2
Reset key
------
(----)
(See notes 1 and
2.)
ffffff
(ffff)
(See notes 1 and
2.)
e1
e2
e2
Main display
2. Display flashes (1-second cycles).
3. Occurs when the present value or the total count value goes below −99,999 (−999 with 4-digit models).
4. Occurs when the present value reaches 999,999 (9,999 with 4-digit models) under the following conditions:
5. Includes the case where the EEPROM has reached its overwrite lifetime.
• The output mode is K-2, D, L, or H.
• The H7CX is set for dual counter operation.
Present value
and output reset.
No effect.
Present value
and output reset.
1-stage/2-stage
No change
No change
Not lit
Not lit
sum
Present value/
set value (1, 2)
Sub-display
counter
Present value and output reset.
Only the total count value is reset. Batch count value and batch output
Present value
and output reset.
Present value/
Present value underflow
(See note 3.)
Present value overflow
(See note 4.)
CPU
Memory error (RAM)
Memory error (EEP)
(See note 5.)
set value
Total and preset counter
Error
Present value,
total count value,
and output reset.
Total count
value
No change
No change
OFF
OFF
OFF
Output status
Present value and output reset.
reset.
Present value
and output reset.
Present value/
set value
Batch counter
Either press the reset key or turn ON
reset input.
Either press the reset key or turn ON
reset input.
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using the
reset key.
Present value,
batch count val-
ue, output and
batch output re-
set.
count set value
Batch count
value/batch
Correction method
Only the CP1 present value is re-
set.
Only the CP2 present value is re-
set.
CP1 present value, CP2 present
value, dual count value, and output
reset.
count set value
Dual count
value/dual
Dual counter
No change
No change
No change
No change
0
Set value after
H7CX-A
present value
CP1 present
value/CP2
reset
29