COUNTER DIGITAL LCD 100-240V NPN

H7BR-CWV-AC100-240

Manufacturer Part Number
H7BR-CWV-AC100-240
Description
COUNTER DIGITAL LCD 100-240V NPN
Manufacturer
Omron
Series
H7BRr
Type
Digital Counterr

Specifications of H7BR-CWV-AC100-240

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
100 V ~ 240 VAC
Display Type
*
Equipment Type
Digital Counter
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7BRCWVAC100240
H7BR
Run Mode
Changing the Set Value
1. Press the DISPLAY Key to change the displayed preset value 1
2. Change the set value from 250 to 1,250.
Setting Mode
Changing Settings in the Function Setting Mode
1. Press the MODE Key to switch from run mode to setting mode.
Examples
and 2 during operation.
Pressing keys 1 through 6 increments the corresponding column
by1.
Non-significant zeros are normally not shown on the set value
display.
The Counter will continue operation if switched from run
mode to function setting mode during operation.
The MODE Key will be locked if the key protection function is
enabled.
Settings changed in the function setting mode are not
effective until run mode is entered. As the operating
conditions will change in this case, always reset operation
with the RESET Key or a reset input.
Batch Set Value Change
(Applicable to Standard Models Only)
1. Selecting Batch Count Display
Switch the count display over to batch count display.
Press the BATCH Key.
2. Batch Set Value Change
Change the batch set value while the batch count is displayed.
Pressing keys 1 through 6 increments the corresponding column by
1.
2. Press the MODE Key to scroll successively through the items
Non-significant zeros are normally not shown on the set value
display.
In order to switch the batch count display over to the count
display, press the DISPLAY Key.
that can be set. Release the MODE Key to select the desired
item.