H7CX-A4D DC12-24Q Omron, H7CX-A4D DC12-24Q Datasheet - Page 21

COUNTER DGTL 4DIGIT 12V SRW TERM

H7CX-A4D DC12-24Q

Manufacturer Part Number
H7CX-A4D DC12-24Q
Description
COUNTER DGTL 4DIGIT 12V SRW TERM
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-A4D DC12-24Q

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4D DC12-24
H7CXA4DDC1224
Z2739
Input Modes and Present Value (See note 1.)
I/O Functions for Counter Operation
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
* Counting starts when the CP1 is turned ON after turning ON the power.
A
A
A
B
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be at least 1/2 the minimum signal width. (See note 2.)
Present value
Present value
Present value
Present value
*CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
0
0
0
UP/DOWN C Quadrature Input Mode
UP/DOWN A Command Input Mode
0
B B B B
1
1
1
UP (Increment) Mode
1
2
2
2
3
3
A
Prohibit
2
A
A
2
Prohibit
2
3
1
1
A
3
A
A
4
2
2
4
5
3
3
5
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
Note: 1. If the configuration selection is set to dual counter, CP1 and
A
A
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
Present value
Present value
Present value
Symbol
Input method
2.
3. The meaning of the H and L symbols in the tables is explained
*CP1
CP2
CP1
CP2
CP1
CP2
CP2 input will operate in the same way as the count input
(CP1) of UP (increment) mode.
must be at least 1/2 the minimum signal width.
If they are less, a count error of 1 may occur.
Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz)
below.
A
H
L
must be greater than the minimum signal width and
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
n
0
n
UP/DOWN B Individual Input Mode
n 1
1
DOWN (Decrement) Mode
n 1
No-voltage input
n 2
2
(NPN input)
Short-circuit
100 s (when maximum counting speed = 5 kHz)
Open
3
A
n 2
Prohibit
2
A
Prohibit
n 3
1
H7CX-A@-N
Voltage input (PNP
1
4.5 to 30 VDC
A
n 3
0 to 2 VDC
input)
A
n 4
2
Counter
n 4
n 5
3
n 5
B
21