H7CX-AW AC100-240 Omron, H7CX-AW AC100-240 Datasheet - Page 35

COUNTER DIGITAL 12VDC 2 STAGE

H7CX-AW AC100-240

Manufacturer Part Number
H7CX-AW AC100-240
Description
COUNTER DIGITAL 12VDC 2 STAGE
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-AW AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 V
Display Type
LCD Programmable Color
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXAWAC100240
Z2740
Output Mode Settings
Output
setting
mode
(LO-LO)
(AREA)
(HI-LO)
(HI-HI)
Upper
Upper
Lower
lower
Area
limit
limit
limit
and
Condition
condition
condition
for OUT1
for OUT2
ON
ON
OUT1 set value ≤ measurement value ≤ OUT2 set
value
measurement value < OUT1 set value
or
measurement value > OUT2 set value
OUT1 set value ≤ OUT2 set value
(Upper-limit) OUT1 set value
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
(Lower-limit) OUT2 set value
(Lower-limit) OUT1 set value
ON condition for OUT1: Measurement value ≥ OUT1 set value
ON condition for OUT2: Measurement value ≥ OUT2 set value
ON condition for OUT1: measurement value ≤ OUT1 set value
ON condition for OUT2: measurement value ≥ OUT2 set value
ON condition for OUT1: Measurement value ≤ OUT1 set value
ON condition for OUT2: Measurement value ≤ OUT2 set value
(Upper-limit) OUT2 set value
Measurement value
Measurement value
Measurement value
Measurement value
OUT1 set value
OUT2 set value
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT2 set value ≤ measurement value ≤ OUT1 set
value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
OUT1 set value > OUT2 set value
H7CX-A