H7CX-A4 AC100-240 Omron, H7CX-A4 AC100-240 Datasheet - Page 62

COUNTER DIGITAL 4DIG SPDT SCREW

H7CX-A4 AC100-240

Manufacturer Part Number
H7CX-A4 AC100-240
Description
COUNTER DIGITAL 4DIG SPDT SCREW
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-A4 AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 V
Display Type
LCD Programmable Color
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4-AC100-240
H7CXA4AC100240
Z2376
Safety Precautions (H7CX-R)
■ Precautions for Safe Use
Changing the Measurement Value
The H7CX-R uses a constant read-in system, so the output status is
affected when the comparison values are changed during operation
such that the present measurement value falls within the range of the
upper- and lower-limit comparison values.
Turning ON the Power using the
Factory Settings
When the power is turned ON using the factory settings, the output
will turn ON after 999.9 s if no pulses are received as count input.
■ Precautions for Correct Use
Comparison Value Settings
In upper and lower limit output mode, if the comparison value setting
is such that comparison value 1 ≥ comparison value 2, the output will
always be ON.
Using the Prescaling Function
Setting the prescale value incorrectly may result in incorrect counting
operation. Be sure to set the prescale value correctly.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
H7CX
62