LD400600 Red Lion Controls, LD400600 Datasheet - Page 4

COUNTER 6 DIGIT 4.0" 120VAC RED

LD400600

Manufacturer Part Number
LD400600
Description
COUNTER 6 DIGIT 4.0" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Counterr
Datasheets

Specifications of LD400600

Count Rate
35kHz
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Voltage - Supply
11 V ~ 16 VDC, 85 V ~ 250 VAC
Display Type
LED Red
No. Of Digits / Alpha
6
Digit Height
101mm
Power Consumption
26VA
Counting Speed
25kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
4"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Wire Leads
Dimensions
26"L×2.25"W×7.875"H
Display Digit Height
4 "
Function
Counter
Material, Casing
Aluminum
Number Of Digits
4
Primary Type
Electronic
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
WIRING OVERVIEW
the meter. All conductors should conform to the meter's voltage and current
ratings. All cabling should conform to appropriate standards of good installation,
local codes and regulations. It is recommended that the power supplied to the
meter (DC or AC) be protected by a fuse or circuit breaker. When wiring the
meter, compare the numbers on the label on the back of the meter case against
those shown in wiring drawings for proper wire position. Strip the wire, leaving
approximately 0.4" (10 mm) bare lead exposed (stranded wires should be tinned
with solder.) Insert the lead under the correct screw clamp terminal and tighten
until the wire is secure. (Pull wire to verify tightness.) Each terminal can accept
up to one #14 AWG (2.55 mm) wire, two #18 AWG (1.02 mm), or four #20
AWG (0.61 mm). Use copper conductors only, with insulation rated at 90°C.
WIRING CONNECTIONS
Access to terminal blocks is through conduit fittings. Remove end plates with
¼" nut driver. For LD4 versions, all wiring is on right side of unit. For LD2
versions, power and input wiring connections are on the right side and the relay
and serial options are on the left side.
plate for proper grounding.
inside the unit (right side). The DC out power is located on TBB (right side).
3.1 POWER WIRING
Power
Terminal 1: VAC/DC +
Terminal 2: VAC/DC -
Terminal 3: Protective Conductor
3.2 RESET/USER INPUT WIRING
Terminal 5: Reset/User
Terminal 6: Comm
3.3 SETPOINT (OUTPUT) WIRING
unit: LD4 (right side) and LD2 (left side).
Terminal 1: NC 1
Terminal 2: NO 1
Terminal 3: Relay 1 Common
Terminal 4: NC 2
Terminal 5: NO 2
Terminal 6: Relay 2 Common
Electrical connections are made via pluggable terminal blocks located inside
Internal removable terminal blocks are used for power and signal wiring.
Connect the drain wire from the shielded cable(s) to the screw on the side
The power wiring is made via the 3 position terminal block (TBA) located
The Reset/User Input is located on the right side.
The setpoint relays use a six position terminal block (TBC) located inside the
Terminal
+
-
2 N.O. 1
3
4
5
6
1 N.C. 1
COMM 1
N.C. 2
N.O. 2
COMM 2
2
3
1
L1
L2
TBC
5
6
DIP switch 6 OFF
Sinking Logic
RESET/USER
COMM
TBA
4
Front
DC Out Power
Terminal 4: + 24 VDC OUT
Terminal 6: User Common
Only programmable models
have terminals TBC and TBD.
TBB
LD4
8
1
-
DIP switch 6 ON
TBA
TBC
TBB
TBD
Sourcing Logic
4
6
5
6
+ EXC
COMM
RESET/USER
COMM
Front
TBD
TBC
LD2 Right Side
LD2 Left Side
TBB
TBA
TBB
TBB
Front