LC4HW-R6-DC24VS Panasonic Electric Works, LC4HW-R6-DC24VS Datasheet

no-image

LC4HW-R6-DC24VS

Manufacturer Part Number
LC4HW-R6-DC24VS
Description
COUNTER DIGITAL 24VDC SCREW TERM
Manufacturer
Panasonic Electric Works
Series
LC4Hr
Datasheet

Specifications of LC4HW-R6-DC24VS

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
12
Input Type
Switch Closure or Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LED Red, Yellow
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1353564
’06–’07
Timers/Time Switches/Counters/Hour Meters
Timers/Time Switches/Counters/Hour Meters
ARCT1B274E ’06.10
Matsushita Electric Works, Ltd.

LC4HW-R6-DC24VS Summary of contents

Page 1

... Timers/Time Switches/Counters/Hour Meters Timers/Time Switches/Counters/Hour Meters ARCT1B274E ’06.10 ’06–’07 Matsushita Electric Works, Ltd. ...

Page 2

... LC4H Counters 48 1.890 64.5 48 4-digit display 2.539 1.890 mm 6-digit display Pin type Screw terminal type RoHS Directive compatibility information http://www.nais-e.com/ Product types Digit Count speed Output mode 4 • Maintain output/hold count • Maintain output/over count • Maintain 30 Hz (cps)/ output/over count II 5 KHz (Kcps) • ...

Page 3

... LC4H/-L LC4H-L Counters 48 1.890 64.5 2.539 48 1.890 mm AEL11 Series (4-digit display) AEL13 Series (6-digit display) Pin type Screw terminal type Product types Digit Count speed Output mode 4 • Maintain output/hold count • Maintain output/over count I • Maintain 30 Hz (cps)/ output/over count II 5 KHz (Kcps) • ...

Page 4

Part names • 4-digit display type Controlled output indicator Reset indicator Lock indicator RESET Reset switch LOCK LC4H Lock switch • 6-digit display type Controlled output indicator ...

Page 5

LC4H/-L Applicable standard Safety standard (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity RF electromagnetic field immunity EMC EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity ...

Page 6

Dimensions for flush mounting (with adapter installed) Screw terminal type: M3.5 Panel Rubber gasket ATC18002 (supplied) COUNTER OP RST 1.969 1.890 LOCK UP RESET LOCK LC4H DOWN 1 .039 48 1.890 • Dimensions for front panel installations ...

Page 7

LC4H/-L Setting the operation mode and set value Setting procedure 1) Setting the operation mode (input mode and output mode) Set the input and output modes with the DIP switches on the side of the counter. DIP switches Item 1 ...

Page 8

Operation modes 1. Input mode For the input mode, you can choose one of the following five modes • Addition UP • Subtraction DOWN • Directive DIR • Independent IND • Phase PHASE Input mode Operation IN1 or IN2 works ...

Page 9

LC4H/-L 2. Output mode For the output mode, you can choose one of the following seven modes • Maintain output/hold count HOLD-A • Maintain output/over count I HOLD-B • Maintain output/over count II HOLD-C • One shot/over count SHOT-A • ...

Page 10

... V DC 100mA Relay / Transistor / LC4H-S LC4H-S Counters 6. Basic insulation between the power supply and the input terminal (only for the sensor type model with power supply) There is no need for caution when con- necting between terminals. 7. Conforms to IP66’s Weather Resistant Standards ...

Page 11

LC4H-S Part names • 4-digit display type Controlled output indicator Reset indicator Lock indicator RESET Reset switch SET/ LOCK LC4H Set/lock switch • 6-digit display type Controlled output indicator Reset indicator Lock indicator RESET Reset switch SET/ LOCK Set/lock switch ...

Page 12

Applicable standard Safety standard (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity RF electromagnetic field immunity EMC EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity Dimensions ...

Page 13

LC4H-S Terminal layouts and Wiring diagrams • Pin type Relay output type Reset Input 1 NC Input Lock – + Operating ~ ~ voltage • Screw terminal ...

Page 14

Setting the operation mode and counter Setting procedure 1) Setting the operation mode (input mode and output mode) Set the input and output modes with the DIP switches on the side of the counter. DIP switches Item 1 2 Output ...

Page 15

LC4H-S E The decimal point is set using the [UP] and [DOWN] keys to specify the 2nd, 3rd, and 4th digits (this applies only to 4-digit models).(The 1st digit is set using the [UP] key or [DOWN] key in settings ...

Page 16

Operation mode 1. Input mode For the input mode, you can choose one of the following five modes • Addition UP • Subtraction DOWN • Directive DIR • Independent IND • Phase PHASE Input mode Operation IN1 or IN2 works ...

Page 17

LC4H-S 2. Output mode For the output mode, you can choose one of the following seven modes • Maintain output/hold count HOLD-A • Maintain output/over count I HOLD-B • Maintain output/over count II HOLD-C • One shot/over count SHOT-A • ...

Page 18

Input connections • Signal input type 1) Open collector (PC, sensor etc.) + Output 0V – 11-pin type Screw-down terminal type 0V Lock Input input 2 3) Contact input Relay, switches etc ...

Page 19

... Counter display UP keys Set value display RESET key Up keys SET/LOCK key LC4H-W Counters 5. Conforms to IP66’s Weather Resistant Standards The water-proof panel keeps out water and dirt for reliable operation even in poor environments. 6. Screw terminal and Pin Type are Both Standard Options ...

Page 20

Specifications Item Rated operating voltage Rated frequency Rated power consumption Rated control capacity Input mode Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) (5 modes selectable by DIP switch) Counting speed Counting input (Input 1, 2) Reset input Rating Input signal Output ...

Page 21

LC4H-W Dimensions • LC4H-W electrical counter 48 1.890 COUNTER OP LOCK RESET SET/LOCK LC4H-W • Dimensions for flush mounting (with adapter installed) Screw terminal type Panel Rubber gasket ATC18002 (supplied) COUNTER OP ...

Page 22

Setting the operation mode and counter Setting procedure 1) Setting the output mode (output 1, 2) Set the output 1 and output 2 with the DIP switches on the side of the counter. The minimum input signal width and maximum ...

Page 23

LC4H-W Operation modes 1. Input mode Q For the input mode, you can choose one of the following five modes. • Addition UP • Subtraction DOWN • Directive DIR • Independent IND • Phase PHASE W After the counter has ...

Page 24

Output mode For the set value 1, you can choose one of the following four modes. • Maintain output/over count I HOLD-B • Maintain output/over count II HOLD-C • Maintain output/over count III HOLD-D • One shot/over count SHOT-A ...

Page 25

LC4H-W • Output mode for set value 2 Output mode Operation Output control is maintained after count-up completion and until resetting. During that time, the count display does not change from that at count-up com- Maintain output pletion. Hold count ...

Page 26

Output mode Operation Output control is maintained after count-up completion for a fixed time (approx. 1 sec). Counting is possible despite completion of count-up. One shot However, reset occurs simultaneous Recount II with output OFF. SHOT-C Output control is maintained ...

Page 27

... Input contact or transistor Input terminal Power supply Input contact or transistor Input terminal When power circuitry is not independent, one input signal can be fed to two or more counters at once, as shown in Fig Fig Input contact or transistor Input terminal Power supply Input terminal Input and output ...

Page 28

The LC4H series use power supply without a transformer (power and input terminals are not insulated). In connect- ing various kinds of input signals, there- fore, use a power transformer in which the primary side is separated from the ...

Page 29

PRECAUTIONS IN USING THE LC4H SERIES 6. Self-diagnosis function If a malfunction occurs, one of the following displays will appear. Display Contents Minimum value went below –999 or or –99999. See note 1. Incorrect DIP switch setting. Malfunctioning CPU. Malfunctioning ...

Page 30

... COUNTERS SELECTOR CHART Classification Name of product LC2H Counter Type Total counter Input mode/Input method UP type Flush mounting type Appearance PC board mounting type AEL3 8.7 mm tall 8-digit display Bright 2-color back light Features Flush mounting type: Unnecessary (Built-in battery) Rated operating voltage ...

Page 31

... TYPICAL COUNTER APPLICATIONS The highly accurate, reliable counters can be controlled from the front panel and are suitable for a wide range of applications. DOWN and HOLD-A modes for shipment quantity counting Photoelectric switch Motor ( stop/start ) Shipment quantities are counted to con- trol the conveyor line flow. ...

Page 32

... COUNTER-RELATED TERMINOLOGY TYPES OF COUNTERS 1. Electro Preset Counter The counter is equipped with semicon- ductor counting circuitry. When the counter counts preset number, its output circuit sends a signal. 2. Electro Magnetic Counter A magnet is magnetized and demagne- tized to drive the dial and count up num- bers. ...

Page 33

PRECAUTIONS IN USING THE COUNTER Cautions for circuits 1. Protective circuit for counter contact In the circuit that switches an inductive load, a contact failure may occur at a contact point due to surge or inrush current resulting from that ...

Page 34

... For the standard values for the LC4H type counters, see the respective items in "Cautions for use." • Single-pole, full-wave voltage for surge waveform [±(1.2 × 50) µs] ...

Page 35

... DIN SIZE COUNTERS COMMON OPTIONS Terminal sockets (Unit: mm Type Appearance • DIN rail socket (8-pin) • DIN rail socket (8-pin) LC4H 24 .945 LC4H-L (8-pin type) 70 2.756 50 1.969 ATC180031 • DIN rail socket (11-pin) • DIN rail socket (11-pin) LC4H 30.5 LC4H-L 1 ...

Page 36

... DIN SIZE COUNTERS COMMON OPTIONS Mounting parts • Rubber gasket 50.0 1.969 1.0 50.0 .039 1.969 ATC18002 The rubber gasket is enclosed in the LC4H series. • Mounting rails (Applicable for 5.5 DIN and IEC standards) .217 AT8-DLA1 Length aluminum • Protective cover for DIN 48 size ...

Page 37

... AT8-DF11K. 6) DIN rail (AT8-DLA1) is also available (1 m). 2. Flush mount 1) For the counters of LC4H series recommended to use the built-in screw terminal type for flush mount. (Mounting frame and rubber gasket are provided when counter is shipped.) 2) How to mount the counter From the panel front, pass the counter through the square hole ...

Page 38

DISCONTINUED MODELS AND RECOMMENDED SUBSTITUTES Timers Discontinued models Recommended substitutes MHP-NS Exposed type MHP-N Exposed type Square plug-in/ Round plug-in/ horizontal type vertical type MHP-NS- MHP-N- MHP-M Exposed type MHP-NM Exposed type Round plug-in/ Round plug-in/ horizontal type vertical type ...

Page 39

Timers Discontinued models Recommended substitutes PM48W PM4H-W PM48W PM4HW- PMH-M PM4H-M/PM4S PMH-M- PM4HM-/PM4S- CDX Time relay S1DXM-A Timer/ S1DX Timer CDX S1DXM-/S1DX- PDX Timer S1DXM-A Timer/ S1DX Timer PDX S1DXM-/S1DX- VHP digital high-power timer QM4H digital timer VHP QM4H QM48S ...

Page 40

... Counters Discontinued models Recommended substitutes MC electromagnetic LC4H counters LC4H MC6 LC4H-L LC48 Relay type: 8-pin LC4H Relay type: 8-pin Tr type: 11-pin Tr type: 11-pin LC4H LC48 LC4H-L LC48W (11-pin) LC4H-W (11-pin) LC48W LC4H-W EM48S (8-pin) LC4H (8-pin) LC4H EM48S LC4H-L EM72S (Screw terminal) ...

Page 41

FOREIGN SPECIFICATIONS OVERVIEW 1. International Standards IEC standard International Electrotechnical Commission By promoting international cooperation toward all problems and related issues regarding standardization in the electrical and electronic technology fields, the IEC, a non-governmental organization, was started in October, 1908, ...

Page 42

Pilot Duty One of the specifications in the “UL508 Industrial Control Equipment” regulations at UL (Underwriters Laboratories Inc.), has to do with the grade of contact control capacity by NEMA (National Electrical Manufacturers Association) standards. By obtaining both UL ...

Page 43

FOREIGN SPECIFICATIONS TIMER Recognized by UL Standards Products Name File No. Recognized rating E43149 5A250VAC PM4S PILOT DUTY C300 PM4H-A E122222 5A250VAC PM4H-S PILOT DUTY C300 PM4H-M PM4H-SD PM4H-W E122222 3A250VAC PM4H-F PILOT DUTY C300 E122222 5A250VAC PILOT DUTY C300 ...

Page 44

... FOREIGN SPECIFICATIONS Counters UL recognized Product name File No. Approved ratings E122222 5A250V AC LC4H PILOT DUTY C300 LC4H-L LC4H-S 100mA 30V DC E122222 3A250V AC PILOT DUTY C300 LC4H-W 100mA 30V DC E122222 24-240 V AC/DC LC2H 4.5- E122222 24-240 V AC/DC LC2H preset 4.5- Hour Meters UL recognized Product name File No ...

Page 45

... QM4H EN 61000-6-4/EN 61000-6-2 A-TB72 EN 61000-6-4/EN 61000-6-2 Time Switch A-TB72Q EN 61000-6-4/EN 61000-6-2 LC4H EN 61000-6-4/EN 61000-6-2 LC4H-L EN 61000-6-4/EN 61000-6-2 LC4H-S EN 61000-6-4/EN 61000-6-2 Counters LC4H-W EN 61000-6-4/EN 61000-6-2 LC2H EN 61000-6-4/EN 61000-6-2 LC2H preset EN 61000-6-4/EN 61000-6-2 TH13 EN 61000-6-4/EN 61000-6-2 TH23 EN 61000-6-4/EN 61000-6-2 TH14 EN 61000-6-4/EN 61000-6-2 TH24 ...