H7CX-A11D1N DC12-24/AC24 Omron, H7CX-A11D1N DC12-24/AC24 Datasheet - Page 34

COUNTER DIGITAL 6DIGIT 12V 11PIN

H7CX-A11D1N DC12-24/AC24

Manufacturer Part Number
H7CX-A11D1N DC12-24/AC24
Description
COUNTER DIGITAL 6DIGIT 12V 11PIN
Manufacturer
Omron
Datasheet

Specifications of H7CX-A11D1N DC12-24/AC24

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 VDC, 24VAC
Display Type
LCD Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXA11D1NDC1224AC24
Z3042
34
H7CX-A@-N
Output Mode Setting and Operation
Tachometer Operation
1 input
Error
Absolute ratio
Error ratio
2 inputs
Input mode
setting
Output mode
Area (AREA)
Upper limit
Lower limit
Upper limit
Lower limit
Upper and
lower limit
(LO-LO)
setting
(HI-LO)
(HI-HI)
(LO)
(HI)
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Output 1
Comparison value 1
Output 1
Comparison value 1
Measurement value
Measurement value
Measurement value
Measurement value
CP1 display value
CP1 display value
ON condition for output 1: CP1 present value (display value)
ON condition for output 2: CP2 present value (display value)
ON condition for output 1: CP1 present value (display value)
ON condition for output 2: CP2 present value (display value)
(Upper-limit)
(Lower-limit)
(Upper-limit)
(Lower-limit)
(Upper-limit)
(Lower-limit)
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT1
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition
for OUT1
ON condition
for OUT2
Condition
Operation
Output 2
Comparison value 2
Output 2
Comparison value 2
CP2 display value
CP2 display value
Comparison value 1
Measurement value
Comparison value 2
Measurement value <
Comparison value 1 or
Measurement value >
Comparison value 2
Comparison value 1
Comparison value 2
OUT2
OUT2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 2
Measurement value
Comparison value 1
Measurement value <
Comparison value 2 or
Measurement value >
Comparison value 1
Measurement value 1 >
Comparison value 2