H7CX-A4-N AC100-240 Omron, H7CX-A4-N AC100-240 Datasheet - Page 33

COUNTER DIGITAL 4DIG SPDT SCREW

H7CX-A4-N AC100-240

Manufacturer Part Number
H7CX-A4-N AC100-240
Description
COUNTER DIGITAL 4DIG SPDT SCREW
Manufacturer
Omron

Specifications of H7CX-A4-N AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 VAC
Display Type
LCD Backlit
No. Of Digits / Alpha
4
Digit Height
12mm
Power Consumption
9.4VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
11.5mm
Supply Voltage Min
100VAC
Panel Cutout Width
45mm
Meter Function
Counter
Rohs Compliant
Yes
Connector Type
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXA4NAC100240
Z3043
Operation in Run Mode
Tachometer Operation
*1 Measurement value 1 for the 2-input input mode.
*2 Measurement value 2 for the 2-input input mode.
*3 Peak/bottom hold enabled
• Set each digit using the individual U Keys.
Displayed when the input mode is not 2 inputs.
Peak hold value
Bottom hold value
*3
Measurement value
Measurement value 1
Comparison value 1
Measurement value 2
Comparison value 2
*1
*2
• Measurement value
• Comparison value 1/Comparison value 2
Displays the currently measured value.
Set comparison value 1 and comparison value 2.
The measurement value is compared to
comparison value 1 and comparison value 2 and
output is made according to the selected output
mode.
Displayed for the 2-input input mode.
Peak hold value 1
Bottom hold value 1
Peak hold value 2
Bottom hold value 2
• Peak/bottom hold value
• Peak/bottom hold value 2
Note: The held values will be initialized when
The peak (maximum) and bottom (minimum)
Peaks (maximums) 1 and 2 and bottoms
values are displayed after counting starts.
(minimums) 1 and 2 are displayed after counting
starts.
the Reset Key (Hold Key) or reset 1 input
is turned OFF while peak/bottom hold
values 1 and 2 are being displayed. (The
reset 2 input operates in the same way if
the input mode is set to 2-input mode.)
H7CX-A@-N
Tachometer
33