Specifications of H7EC-NFV-B

Count Rate
1kHz
Number Of Digits/alpha
8
Input Type
Voltage
Voltage - Supply
None Required (Battery Included)
Display Type
LCD Non-Backlit
Voltage Rating
24 VAC/DC to 240 VAC/DC
Mounting
Flush Mounting Adapter
No. Of Digits / Alpha
8
Digit Height
8.6mm
Counting Speed
20Hz
Operating Temperature Range
-10°C To +55°C
Height
0.94"
Mounting Type
Flush
Panel Cutout Width
45mm
Width
1.89"
Signal Input Type
Voltage
Equipment Type
Self-Powered Count Totalizer
Dimensions
48 mm L x 24 mm W x 48.5 mm H
Mounting Style
Panel
Primary Voltage Rating
24 V to 240 V
Termination Style
Screw
Depth
1.91"
Ip/nema Rating
IP66 / NEMA 4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H7EC-FBV
H7ECNFVB
Z867

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7EC-NFV-B
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Operation
■ Operating Modes
Nomenclature
Note: Perform switch setting before mounting to a control panel.
H7ET Time Counter
Incrementing Operation
(Up)
(see note)
Terminal block
Front panel
Setting
Timer display values
Concave
side
Concave
side
Internal clock
timer value
Timer input
0.0h to 3999d23.9h
H7ET-N@@-@@
0.0h to 999999.9h
Reset
(default setting)
Time range
Time-range switch
If the time-range setting is
changed, the present
value will not be held and
so press the Reset Key on
the front panel.
0.0min to 9999h59.9min
0s to 999h59min59s
(Full-scale
−0.1 (1))
H7ET-N@@1-@@
(default setting)
Full-scale
H7ET
Front view
Bottom view
Reset Key
Reset the count value. Not operable
under key-protect.
Key-protect Switch
The Reset Key is not operable while the
key-protect switch is set to ON.
(see note)
Terminal block
Setting
Front panel
Concave
side
Concave
side
(default setting)
Key-protect
OFF
ON
New H7ET