SET-3A Omron, SET-3A Datasheet - Page 41

no-image

SET-3A

Manufacturer Part Number
SET-3A
Description
CONVERTER CURRENT 1-80A FOR SAO
Manufacturer
Omron
Series
SAOr
Datasheets

Specifications of SET-3A

Accessory Type
Current Converter
For Use With/related Products
SAO Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SET3A
Engineering Data
Insulation resistance
Withstand voltage
Lighting impulse withstand voltage
Overload capacity
Vibration resistance
Shock resistance
Test button operation
Ambient temperature
Ambient humidity
Altitude
Weight
SAO-R
Time Changeover Setting: 1
SAO-S
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
Characteristics (continued)
Operating Time Characteristics
80
70
60
50
40
30
20
10
0
0
100
100
Current (% of current SV)
Current (% of current SV)
200
200
Time scale value
300
300
10
8
6
4
2
1
400
400
500
500
600
600
10 M min. between electric circuits and the mounting panel
5 M
2,000 VAC for 1 min between electric circuits and the mounting panel
2,000 VAC for 1 min between contact circuits and other circuits
1,000 VAC for 1 min between contacts of same pole
6,000 V max. between electric circuits and the mounting panel
4,500 V max. between contact circuits and other circuits
4,500 V max. between each control power circuits
Waveform: 1.2 x 50 s 3 times for each poles
Motor circuit:
Continuous current:
Power supply: AC:
Malfunction: 10 to 55 Hz, 0.3-mm double amplitude each in 3 directions for 10 min
Destruction: 10 to 25 Hz, 2-mm double amplitude each in 3 directions for 2 hrs
Malfunction: 98 m/s
Destruction: 294 m/s
Operated quickly (without lighting the LED)
Operating:
Storage:
Operating: 35% to 85%
2,000 m max.
Approx. 170 g
SAO-SU
Operating Time Characteristics
Time Changeover Setting: 4
0.1
0.4
0.3
0.2
320
280
240
200
160
120
min. between contact circuits, or between contacts of same pole
80
40
0
0
100
–10 to 60 C (with no icing)
–25 to 65 C (with no icing)
Current (% of operating current)
DC:
20
Current (% of current SV)
200
2
2
(approx. 10G) each in 3 directions
20 times the current SV for 2 s, applied twice with a 1 min interval
125% of the maximum current SV for each current range.
1.15 times the rated power supply voltage for 3 hrs, once
1.3 times the rated power supply voltage for 3 hrs, once
Time scale value
(approx. 30G) each in 3 directions
40
300
10
8
6
4
2
1
400
60
500
80
600
100
SAO-Q
0.1
0.4
0.3
0.2
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
Reset Time Characteristics
100
0
0
100
Current (% of operating current)
120
Current Sensor
Current (% of current SV)
200
140
300
400
160
500
SAO
180
600
200
39