117510000 Weidmuller, 117510000 Datasheet - Page 22

DIN RAIL SLOTTED TS 15X5.5 1M

117510000

Manufacturer Part Number
117510000
Description
DIN RAIL SLOTTED TS 15X5.5 1M
Manufacturer
Weidmuller
Datasheet

Specifications of 117510000

Size
0.591" W x 0.217" H (15.00mm x 5.50mm)
Length
39.370" (1000.00mm)
Slotted/unslotted
Slotted
Thickness
0.039" (1.00mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
11751
117510000
281-1535
TS 15
F
Busbars
In switchgears and controls, it may be necessary
to bring the neutral conductor and the protective
conductor together at a central point. Busbars are
available for this purpose and can be used for con-
necting a large number of conductors in a con-
fined space (up to 70 conductors on a 1 m bus-
bar). The conductors are connected by means of a
pressure piece or tension clamp; the former does
not entail bending the eyelets. A guide lug on the
pressure piece engages in the busbar and holds
the pressure piece firmly so that it cannot twist.
The tension clamps can be pushed on the busbar
and adjusted to the entire wiring in the system.
The busbars can be used unperforated in any
lengths. They are fixed using the SH busbar holder
which can, for longer busbars, also be positioned
between the tension clamps.
Busbars, unperforated
Busbars, perforated
F.22
Busbar systems
Tension clamps
SSch
NSch / ESch
Connection data NSch/ESch
Screw connection solid
Stripping length
Cable lug connection
Max. current per connection
Type
SSch 10x3
SSch 10x3
SSch 10x3
SSch 6x6
SSch 6x6
SSch 15x6
Type
NSch 15x2
ESch 12x2
Pressure piece
DKSUE
Clamping screw
BFSC M5x8
Material
Copper, tin-plated
Steel, galvanised
Brass, bright
Copper, tin-plated
Brass, bright
Copper, tin-plated
Material
Copper, bright
Steel, galvanised
Articles with coloured order number are kept permanently in stock at the central warehouse in Germany.
(see page F.24 – F.25)
Cross-section
10 x 3 mm
10 x 3 mm
10 x 3 mm
6 x 6 mm
6 x 6 mm
15 x 6 mm
Cross-section
15 x 2 mm
12 x 2 mm
0.5 ... 2.5 mm
9 mm
max. 16 mm
27 A
Length
1 m
1 m
1 m
1 m
1 m
1 m
Length
1 m
1 m
2
2
In order to bring together neutral conductors and
protective conductors at a central point, it is ad-
vantageous to use ZB tension clamps together
with 10 x 3 or 6 x 6 busbars. The tension clamps
can be pushed onto the busbar and adjusted to
the entire wiring in the system.
The tension clamp serves as the protective con-
ductor connection and can be supplied with
green/yellow insulating caps. These caps indicate
the protective function and marking tags allow
clear identification of each conductor.
If the tension clamps are used to connect neutral
conductors, they can be marked with a blue insu-
lating cap.
ZBE6 can also be swivelled onto the busbar retro-
spectively.
Current carrying capacity Qty
140 A
100 A
140 A
100 A
265 A
Power Rating
80 A
Delivery times see page X.2
Qty
Qty
100
Qty
100
1
1
1
1
1
1
1
1
Order no.
0348900000
0438000000
0259800000
0571300000
0571200000
0357400000
Order no.
0280200000
0280300000
Order no.
0280100000
Order no.
0296700000

Related parts for 117510000