SI8662EC-B-IS1 Silicon Laboratories Inc, SI8662EC-B-IS1 Datasheet - Page 14

IC ISOLATOR 6CH 3.75KV 16-SOIC

SI8662EC-B-IS1

Manufacturer Part Number
SI8662EC-B-IS1
Description
IC ISOLATOR 6CH 3.75KV 16-SOIC
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI8662EC-B-IS1

Number Of Channels
6
Supply Voltage (max)
3.75 KV
Mounting Style
SMD/SMT
Package / Case
SOIC-16 Narrow
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-2126-5
Si8660/61/62/63
Table 5. Regulatory Information*
Table 6. Insulation and Safety-Related Specifications
14
CSA
The Si866x is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 600 V
60950-1: Up to 600 V
age.
60601-1: Up to 125 V
VDE
The Si866x is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
60747-5-2: Up to 1200 V
60950-1: Up to 600 V
age.
UL
The Si866x is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 5000 V
*Note: Regulatory Certifications apply to 3.75 kV
Parameter
Nominal Air Gap (Clearance)
Nominal External Tracking
(Creepage)
Minimum Internal Gap
(Internal Clearance)
Tracking Resistance
(Proof Tracking Index)
Erosion Depth
Resistance (Input-Output)
Capacitance (Input-Output)
Input Capacitance
Notes:
1. The values in this table correspond to the nominal creepage and clearance values. VDE certifies the clearance and
2. To determine resistance and capacitance, the Si86xx is converted into a 2-terminal device. Pins 1–8 are shorted
3. Measured from input pin to ground.
Regulatory Certifications apply to 5.0 kV
For more information, see "5. Ordering Guide" on page 26.
creepage limits as 4.7 mm minimum for the NB SOIC-16 package and 8.5 mm minimum for the WB SOIC-16 package.
UL does not impose a clearance and creepage minimum for component-level certifications. CSA certifies the clearance
and creepage limits as 3.9 mm minimum for the NB SOIC-16 package and 7.6 mm minimum for the WB SOIC-16
package.
together to form the first terminal and pins 9–16 are shorted together to form the second terminal. The parameters are
then measured between these two terminals.
1
3
RMS
RMS
RMS
RMS
RMS
isolation voltage for basic protection.
peak
2
reinforced insulation working voltage; up to 600 V
reinforced insulation working voltage; up to 1000 V
reinforced insulation working voltage; up to 380 V
reinforced insulation working voltage; up to 1000 V
2
1
for basic insulation working voltage.
Symbol
L(IO1)
L(IO2)
RMS
PTI
R
C
ED
C
RMS
IO
IO
I
rated devices which are production tested to 6.0 kV
rated devices which are production tested to 4.5 kV
Rev. 1.2
Condition
IEC60112
f = 1 MHz
Test
SOIC-16
0.014
0.019
10
RMS
RMS
WB
600
8.0
8.0
2.0
4.0
RMS
RMS
12
basic insulation working voltage.
basic insulation working voltage.
basic insulation working volt-
basic insulation working volt-
Value
SOIC-16
0.019
0.011
4.01
10
600
NB
4.9
2.0
4.0
RMS
12
RMS
for 1 sec.
for 1 sec.
V
Unit
mm
mm
mm
mm
RMS
pF
pF

Related parts for SI8662EC-B-IS1