4420.0388 Schurter Inc, 4420.0388 Datasheet

no-image

4420.0388

Manufacturer Part Number
4420.0388
Description
CBE AS168X-CB3G040
Manufacturer
Schurter Inc
Type
Thermal/Magneticr
Datasheet

Specifications of 4420.0388

Actuator Type
Handle
Alt Mfr.s Type
AS168X-CB3G040
Brand/series
AS168 Series
Color, Actuator
Black
Current, Rating
4 A
Mounting Type
DIN Rail
Number Of Poles
3
Standards
UL Recognized, CSA Certified
Termination
Screw
Thread Length
0.625
Voltage, Rating
480 VAC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR
Product description
The AS168X is a thermal magnetic high performance CBE to IEC 934
and a «supplementary protector» to UL 1077. It is capable of drasti-
cally limiting the «let-through energy» in case of short circuit interrup-
tions. The series is available in units from one to four poles for use in
AC and DC circuits. Multipole devices are connected internally and at
the handle for simultaneous operation. This applies also to combina-
tions with the switched neutral pole. Well designed screw type term-
inals at line and load side are provided for safe and easy connection
to line and load. They accept #16 to 4 AWG / 1,5 to 25 mm
The AS168X is suitable as supplementary protector under
UL 1077 / EN 60934 or as Manual Motor Controller according
UL 508 / CSA 22.2 14. Thus the Breaker has a high versatility
and is suitable for many functions:
• Motor overload protection (thermal and magnetic)
• Motor starting across-the-line (direct-on-line)
• Motor starting with motor disconnect (cos phi 0,4 – 0,5)
• Motor group installation (short capacity 5 kA)
• Control circuits
Accessories
• Auxiliary contact module
• Signal contact module
• Relay trip module
• Switched neutral pole (factory assembled)
Features
• Excellent short circuit performance (up to 10 kA)
• High limits of discrimination (due to energy limitation)
• Wide choice of characteristics (Adaptability)
• Availability of AC and DC in the same frame size
• Compact, «finger safe» design
• Ease installation (on DIN rail)
Applications
• Industrial machines
• Automation
• Aircondition, ventilation
• Transformers
• Power supplies
• Telecom systems
• Computer systems
• Test systems
• Medical equipments
Each auxiliary contact module contains one contact,
either normally open or normally closed.
Signal contact modules are linked internally with the protected
poles but not linked at the handles.
Contacts are actuated by a fault condition at the protected poles,
not by the manual operation of the CBE.
The relay trip module can be used for remote tripping of the
adjacent poles by applying a voltage to the module’s terminal.
This module allows to automatically open the neutral line when
the protected poles have been tripped.
2
.
www.schurterinc.com
AS168X
123

Related parts for 4420.0388

4420.0388 Summary of contents

Page 1

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Product description The AS168X is a thermal magnetic high performance CBE to IEC 934 and a «supplementary protector» 1077 capable of drasti- cally limiting the «let-through energy» in case of ...

Page 2

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Effect of ambient temperature AC-breakers are calibrated for an ambient temperature of +40°C, DC-breakers for +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the ...

Page 3

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Tripping characteristic DF 1hr 1000s 100s 10s 1s 0,1s 10ms 1ms 0,1ms 1 10 100 1000 Multiple of rated current ( Technical data Pole : Rated voltage U ...

Page 4

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Technical data (continued) Add-on modules Auxiliary contact H1 & H2 and Signal contact S1 & S2 Functional auxiliary contact module Functional signal contact Relay trip module Function of relay trip module General data Dielectric ...

Page 5

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Approvals AC versions EN 60934 Poles Characteristic/ Volt 420/240 420/240 0 420/240 0 ...

Page 6

MANUAL MOTOR CONTROLLER AND SUPPLEMENTARY PROTECTOR Conversion table Ampere rating – Horsepower rating Voltage Rating: One pole: Two pole: Three pole: HP-Rating: 1 phase (1 pole & 2 pole): AS168X-CB MOTOR NAMEPLATE Rated Current FLA Starting/ (See Note #1) Rating ...

Related keywords