4302.5313 Schurter Inc, 4302.5313 Datasheet

MOD PWR ENTRY STD 2POS SW 4A PNL

4302.5313

Manufacturer Part Number
4302.5313
Description
MOD PWR ENTRY STD 2POS SW 4A PNL
Manufacturer
Schurter Inc
Series
KFB2r
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 4302.5313

Filter Type
General Purpose
Termination Style
Quick Connect - .250" (6.3mm)
Current
4A
Features
Shielded, Switch On/Off, Non-Illuminated
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Screw Hole
Voltage
250V
Filtered
Yes
Product
Modules
Current Rating
4 A
Voltage Rating
125 V / 250 V
Housing Material
Thermoplastic
Mounting Style
Screw
Operating Temperature Range
- 25 C to + 85 C
Flammability Rating
UL 94 V-0
Length
59 mm
Width
30 mm
Connector Type
IEC-320 C-14
Capacitance, Cx
68
Capacitance, Cy
2.2
Current, Leakage
<0.5 mA
Current, Rating
4 A
Cut Out, Panel
28.5×43 mm
Dielectric Strength
>1.7 kVDC (L-N), >2.7 kVDC (L/N-PE)
Gender
Male
Inductance
2×1.5 mH
Material, Housing
Thermoplastic
Mount Method
Front
Number Of Poles
2
Temperature, Operating
-25 to +85 °C
Termination
Quick Connect
Thickness, Panel
8 mm
Version
Standard
Voltage, Rating
125 VAC (UL/CSA), 250 VAC (IEC)
Connector Mounting
Panel
Contact Termination
Quick Connect
Body Material
Thermoplastic
Rohs Compliant
Yes
Approval Categories
UL Recognized, CSA Certified, VDE Approved
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
4302.5313
Quantity:
1
Power Entry Modules with Line Filter
Description
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, Line Switch 2-pole, Line filter in stan-
- Quick connect terminals 6.3 x 0.8 mm
Approvals
- VDE Certificate Number: 40004665 (FKT)
- UL File Number: E72928 (FKT)
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
IEC Appliance Inlet C14 with Filter, Line Switch 2-pole
dard and medical version
70° C
C14
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
EMC Products
Characteristics
- All single elements are already wired
- Line switch non-illuminated
- With EMC-shield
- Qualified for use in equipment according IEC/EN 60950
References
Alternative: version without line filter KEB2
We recommend for new applications the new type DC12
Weblinks
General Product Information, Approvals, RoHS, CHINA-RoHS, Mating
Connectors, e-Store, SCHURTER-Stock-Check, Distributor-Stock-
Check, Accessories
Appliance-Inlet/-Outlet
Line Switch
Line Filter
MTBF
www.schurter.com/pg06
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 1'900'000 h acc. to MIL-HB-217 F
Standard- or Medical-Filter
KFB2


Related parts for 4302.5313

4302.5313 Summary of contents

Page 1

Power Entry Modules with Line Filter IEC Appliance Inlet C14 with Filter, Line Switch 2-pole C14 70° C Description - Panel Mount: Screw-on mounting from front side - 3 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Line filter in stan- dard and medical version - Quick connect terminals 6.3 x 0.8 mm Approvals - VDE Certificate Number: 40004665 (FKT File Number: E72928 (FKT) Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC °C / 250 VAC Ratings UL/CSA °C / 125 VAC Leakage Current standard < 0.5 mA (250 Hz) medical < 5 µA (250 Hz) Dielectric Strength ...

Page 2

KFB2 www.schurter.com/pg06 Dimensions +1 30.5 – 4.5 R 3.1 27.2 Technical Data of Filter-Components Rated Current Filter-Type [A] 1 Standard Version 2 Standard Version 4 Standard Version 6 Standard Version 10 Standard Version 1 Medical Version ...

Page 3

... Standard version Medical version (M5 Variants Rated Current Filter-Type Order Number [A] 1 Standard Version 4302.5311 2 Standard Version 4302.5312 4 Standard Version 4302.5313 6 Standard Version 4302.5314 10 Standard Version 4302.5315 1 Medical Version (M5) 4302.5331 2 Medical Version (M5) 4302.5333 4 Medical Version (M5) 4302.5335 6 Medical Version (M5) 4302.5337 10 Medical Version (M5) 4302.5339 ...

Page 4

KFB2 www.schurter.com/pg06 Accessories Description Assorted Covers Rear Cover Cord retaining kits Cord retaining strain relief Flat head, A Mating Outlets/Connectors Category / Description Appliance OutletOverview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal IEC Appliance Outlet F, ...

Related keywords