4301.5004 Schurter Inc, 4301.5004 Datasheet

MOD PWR ENT 2POS HLDR 6A QC PNL

4301.5004

Manufacturer Part Number
4301.5004
Description
MOD PWR ENT 2POS HLDR 6A QC PNL
Manufacturer
Schurter Inc
Series
KFAr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 4301.5004

Current
6A
Features
Fuse Holder
Filter Type
General Purpose
Fuse Drawer
Sold Separately
Mounting Type
Panel Mount, Screw Hole
Termination Style
Quick Connect - .250" (6.3mm)
Voltage
250V
Gender
Plug
Voltage Rating
250VAC
Current Rating
6A
Connector Mounting
Panel
Contact Termination
Quick Connect
Fuse Size
5 X 20 Mm
Connector Type
Filtered / Fused Power Entry
Capacitance, Cx
68
Capacitance, Cy
2.2
Color
Black
Current, Leakage
<0.5 mA
Current, Rating
6 A
Cut Out, Panel
33×29 mm
Dielectric Strength
>1.7 kVDC (L-N), >2.7 kVDC (L/N-PE)
Flammability Rating
UL94 V-0
Inductance
2×0.8 mH
Material, Housing
Thermoplastic
Mount Method
Front
Number Of Poles
2
Standards
UL Recognized, CSA Certified, VDE and IEC Approved
Temperature, Ambient
-25 to +85 °C
Temperature, Operating
-25 to +85 °C
Termination
Quick Connect
Thickness, Panel
8 mm
Version
Standard
Voltage, Rating
125 VAC (UL/CSA), 250 VAC (IEC)
Body Material
Thermoplastic
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
K K F F A A
With fuseholder 5x20 mm, with or without voltage selector (step switch)
D D e e s s c c r r i i p p t t i i o o n n
- Panel Mount:
- 4 Functions:
- Quick connect terminals or wires
- Alternative: version without line filter KEA
A A p p p p r r o o v v a a l l s s
- VDE License Number: 40004665
- UL License Number: E76360
T T e e c c h h n n i i c c a a l l D D a a t t a a
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminals
Panel Thickness s
Material: Housing
Screw-on mounting
from front side
with voltage selector
81
Screw-on version from front or rear side, snap-in version from front
side
Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm 1- or 2-
pole, with or without voltage selector (step switch), Line filter in stan-
dard and medical version
70° C
C14
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals or wires
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, Black, UL 94V-0
Screw-on mounting
from rear side
without voltage selector
POWER ENTRY MODULES WITH LINE FILTER
- Rear side mounting for efficient costsaving assembly
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
- Qualified for use in equipment according IEC/EN 60950
- Capacity CX 100 nF
General Product Information see page
Approvals:
RoHS:
Appliance-Inlet /-Outlet
Fuseholder
Rated Power Acceptance @ Ta
23 °C
Power Acceptance @ Ta > 23°C Admissible power acceptance at higher
Voltage selector
Line Filter
MTBF
C C h h a a r r a a c c t t e e r r i i s s t t i i c c s s
O O t t h h e e r r v v e e r r s s i i o o n n s s o o n n r r e e q q u u e e s s t t
R R e e f f e e r r e e n n c c e e s s
W W e e b b l l i i n n k k s s
Suitable for assembly in metal plated plastic housings
The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
Screw-on mounting
from front side
without voltage selector
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold con-
dition) pin-temperature 70 °C, 10 A, Pro-
tection class I
1- or 2-pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per
pole
ambient temperature see derating curves
optional, step, 3 digits
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details see WEBXXX
> 1'700'000 h acc. to MIL-HB-217 F
282
Plug removal necessary for fuse
replacement

Related parts for 4301.5004

4301.5004 Summary of contents

Page 1

With fuseholder 5x20 mm, with or without voltage selector (step switch) Screw-on mounting from front side with voltage selector C14 70° ...

Page 2

Length Screw-on mounting from front side R6 R3.1 230 R4.5 31 with ...

Page 3

...

Page 4

Standard version 1 A ...

Page 5

... 3 digits 4301.5052 4301.5002 3 digits 4301.5042 4301.7012 4301.7002 4301.7004 4301.5013 3 digits 4301.5053 4301.5003 3 digits 4301.5043 4301.7013 4301.7003 4301.7006 4301.5014 3 digits 4301.5054 4301.5004 3 digits 4301.5044 4301.7014 4301.7004 4301.7208 4301.5015 3 digits 4301.5055 4301.5005 3 digits 4301.5045 4301.7015 4301.7005 4301.7000 4301.6201 4301.6203 4301.6205 4301.6206 4301.6209 4301.6207 3 digits 4301 ...