5120.1007.0 Schurter Inc, 5120.1007.0 Datasheet

MODULE PWR ENTRY 15A 250V SCREW

5120.1007.0

Manufacturer Part Number
5120.1007.0
Description
MODULE PWR ENTRY 15A 250V SCREW
Manufacturer
Schurter Inc
Series
5120r
Type
IEC 320-C18 (Male Pins)r
Datasheets

Specifications of 5120.1007.0

Filter Type
General Purpose
Termination Style
Quick Connect - .250" (6.3mm)
Current
15A
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Screw Hole
Voltage
250V
Filtered
Yes
Product
Modules
Current Rating
15 A
Voltage Rating
250 VAC
Housing Material
Steel Tin Plated Thermoplastic
Mounting Style
Screw
Operating Temperature Range
- 25 C to + 85 C
Flammability Rating
UL 94 V-0
Inductance
0.1 mH
Connector Type
IEC-320 C-14/C-18
Capacitance, Cx
100
Capacitance, Cy
2.2
Current, Leakage
<0.5 mA
Current, Rating
15 A
Cut Out, Panel
30.5×22.5 mm
Dielectric Strength
>1.7 kVDC (L-N), >2.7 kVDC (L/N-PE)
Gender
Male
Material, Housing
Thermoplastic
Mount Method
Rear
Number Of Poles
2
Temperature, Operating
-25 to +85 °C
Termination
Quick Connect
Thickness, Panel
8 mm
Version
Standard
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Power entry modules with line filter
 
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
- 2 Functions:
Appliance Inlet, protection class I or II, Line filter in standard and medi-
Approvals
- VDE License Number: 40016382
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Inlet filter, ECO design, front- or rear side mounting, protection class I or II
side
cal version Quick connect terminals 6.3 x 0.8 mm
70° C
C14
70° C
C18
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 2 mm
(all steps with one variant)
Themoplast / steel tin-plated, black /
metallic, UL 94V-0
 
EMC products
Characteristics
- Compact high performance filter
Optimal shielding due to completely closed filter case, unpotted
- Designed for standard and medical applications
Suitable for assembly in metal plated plastic housings
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Snap-in for panel thickness >2mm to 3mm
- Solder terminals
- Class X1 capacitor for enhanced surge withstand voltage
- Medical version M80
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
Appliance-Inlet/-Outlet
Line Filter
MTBF
Snap-in mounting from front side 
Protection class II
C14/C18 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I or II
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 3'000'000 h acc. to MIL-HB-217 F
Standard- or Medical-Filter
520


Related parts for 5120.1007.0

5120.1007.0 Summary of contents

Page 1

Power entry modules with line filter Inlet filter, ECO design, front- or rear side mounting, protection class   C14 C18 70° C 70° C Description - Panel Mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Appliance Inlet, protection class I or II, Line filter in standard and medi- cal version Quick connect terminals 6.3 x 0.8 mm Approvals - VDE License Number: 40016382 - UL License Number: E72928 Technical Data Ratings IEC °C / 250 VAC Ratings UL/CSA ...

Page 2

Dimensions Length Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting) 48.6 40 3.6 Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting) 48 Dimensions for class II version also apply to class I Snap-in mounting from front side 32.6 Dimensions for class I version also apply class II 2 54.5 mm 54.5 12 39.5 3 54.5 12 39.5 3 54.5 12 39.5 3 EMC products Power entry modules with line filter 12 29 ±0.1 ...

Page 3

Power entry modules with line filter Technical Data of Filter-Components Rated Current Filter-Type [A] 1 Standard Version 2 Standard Version 4 Standard Version 6 Standard Version 10 Standard Version 15 Standard Version 1 Medical Version (M5) 2 Medical Version (M5) 4 Medical Version (M5) 6 Medical Version (M5) 10 Medical Version (M5) 15 Medical Version (M5) 1 Bleed Resistor Version ...

Page 4

... EMC products Power entry modules with line filter 6 A Distributor-Stock-Check | SCHURTER-Stock-Check | e-Store Protection Class Order Number I 5120.0000.0 I 5120.0001.0 I 5120.0003.0 I 5120.0004.0 I 5120.0006.0 I 5120.0007.0 I 5120.1000.0 I 5120.1001.0 I 5120.1003.0 I 5120.1004.0 I 5120.1006.0 I 5120.1007.0 I 5120.2000.0 I 5120.2001.0 I 5120.2003.0 I 5120.2004.0 I 5120.2006.0 I 5120.2007.0 I 5120.0300.0 I 5120.0301.0 I 5120.0303.0 I 5120.0304.0 I 5120.0306.0 I 5120.0307.0 I 5120.1300.0 I 5120.1301.0 I 5120 ...

Page 5

Power entry modules with line filter Rated Cur- Filter-Type Panel mounting rent [A] 15 Medical Version (M5) Snap-in 2 Medical Version (M5) Screw-on/Rivet 4 Medical Version (M5) Screw-on/Rivet 6 Medical Version (M5) Screw-on/Rivet 1 Medical Version (M5) Screw-on 2 Medical Version (M5) Screw-on 4 Medical Version (M5) Screw-on 6 Medical Version (M5) Screw-on 10 Medical Version (M5) Screw-on ...

Related keywords