M7F4D1G Omron, M7F4D1G Datasheet - Page 9

no-image

M7F4D1G

Manufacturer Part Number
M7F4D1G
Description
Manufacturer
Omron
Datasheet

Specifications of M7F4D1G

Display Type
Segmented
Emitting Color
Green
Number Of Digits
4
Package Type
Panel
Operating Temperature Classification
Commercial
Pin Count
20
Opto Display Type
Panel
Pattern Type
Segmented
Lead Free Status / RoHS Status
Supplier Unconfirmed
■ External Connections
Refer to Block Diagram on page 8 and Terminal Arrangement on
page 7 for external connections for the M7F according to the signal
input method.
PLC Connections
• Refer to your PLC operation manual before connecting the PLC.
• The M7F connects to the PLC without using any external resistor.
• It is necessary to select the correct input method of the M7F
• A PLC Dynamic Output Unit can be used to save wiring. Use a
according to the output method of the PLC Output Unit. Refer to
Connectable PLCs on page 2 for details on the selection of the
correct input method.
dynamic input model (M7F-@D@@@).
Note: 1. Use the M7F positive logic input model if the PLC Output Unit has PNP output.
PLC Output
Unit
PLC
With PLC Static Output Unit
1. M7F-@P@@@ Static Positive Logic Input Model
Connected to C500-OD212 Output Unit
Terminal
name
2. The PLC connects to the M7F with ease via the enclosed G79-Y@C Cable (with
connectors, sold separately).
Termi-
nal No.
DC power
supply (+)
12 to 24 VDC
(0 V)
Power
supply
input
Power
supply
input
Circuit Configuration
PLC
0 V
A to D
0 V
M7F
9