ECX09H1BJA-R63/D EATON, ECX09H1BJA-R63/D Datasheet - Page 4

Starter,240 VAC-HOA W Red,9-45 Amps

ECX09H1BJA-R63/D

Manufacturer Part Number
ECX09H1BJA-R63/D
Description
Starter,240 VAC-HOA W Red,9-45 Amps
Manufacturer
EATON
Datasheet

Specifications of ECX09H1BJA-R63/D

Supply Voltage Range
200V To 240V
No. Of Phases
1 Or 3
Power Rating
1hp
Current Rating
32A
Operating Temperature Range
-25°C To +50°C
Peak Reflow Compatible (260 C)
No
Supply Voltage Max
240V
Rohs Compliant
No
Leaded Process Compatible
No
4
4-4
Cover Control
Non-combination Starters
Control Power Transformer (CPT) may be required.
Combination Starters
Table 4-3. Type 1 Non-combination Cover Control
Non-reversing
Reversing
Description
No Cover Mounted Pilot Devices
START/STOP Pushbuttons
HAND/OFF/AUTO Selector Switch
Red RUN Pilot Light
Green OFF
Red RUN/Green OFF Pilot Lights
No Cover Mounted Pilot Devices
FOR/REV/STOP Pushbuttons
UP/STOP/DOWN Pushbuttons
Two Red Pilot Lights
One Green Pilot Light
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with 2 Red Pilot Lights
with 2 Red Pilot Lights
For more available factory installed flange control, see Table 4-4.
Add Code Letter from the table below to Catalog Number for voltage —
Kits only. Example: C400T9B.
Cover control for Combination Starters uses 10250T style
devices as standard.
E22 style cover control options are available (Table 4-5).
Selector switches are maintained with lever operators.
Pushbuttons are momentary type with extended
pushbutton.
The kit includes hardware and connecting wires (where
possible).
For factory installed control devices other than shown
below, refer to Modification Codes, Page 16-40.
Rating
120V 60 Hz
208V 60 Hz
240V 60 Hz
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
Code
Letter
A
E
B
Type 1 Cover Control
Rating
277V 60 Hz
380V 50 Hz
Factory Installed
Flange Control
Position
9 Code
A
B
C
D
H
J
K
P
Q
R
A
B
C
E
F
P
Q
Code
Letter
H
L
Rating
480V 60 Hz
600V 60 Hz
For more information visit: www.eaton.com
Field
Installation Kits
Catalog
Number
C400GK0
C400GK1
C400GK12
C400GK16
C400GK3
C400GK32
C400GK36
C400GK42
C400GK41
C400GK46
C400GK0
C400GR1
C400GR14
C400GR2
C400GR24
C400GK44
C400GK41
Code
Letter
C
D
Table 4-4. Type 1 Combination and All Type 3R, 4X and 12
Cover Control
Non-reversing
Reversing
Description
No Cover Mounted Pilot Devices
START/STOP Pushbuttons
ON/OFF Pushbuttons
HAND/OFF/AUTO Selector Switch
START Pushbutton
ON Pushbutton
OFF Pushbutton
Red RUN Pilot Light
Green OFF
Red RUN/Green OFF Pilot Lights
START/STOP Selector Switch
ON/OFF Selector Switch
No Cover Mounted Pilot Devices
FOR/REV/STOP Pushbuttons
UP/STOP/DOWN Pushbuttons
FOR/OFF/REV Selector Switch
Two Red Pilot Lights
One Green Pilot Light
Two Red/One Green Pilot Lights
OPEN/OFF/CLOSE Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
with 2 Red Pilot Lights
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
For Type 1 Non-combination field installation kits, see Table 4-3.
Add Code Letter from the table below to Catalog Number for voltage —
Kits only. Example: C400T9B.
Order Quantity (2) of C400T10.
Rating
120V 60 Hz
208V 60 Hz
240V 60 Hz
Code
Letter
A
E
B
10250T Selector Switch
Rating
277V 60 Hz
380V 50 Hz
Factory Installed
Flange Control
Position
9 Code
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
A
B
C
D
E
F
H
J
K
P
Q
R
V
W
X
Code
Letter
H
L
Rating
480V 60 Hz
600V 60 Hz
Field
Installation Kits
Catalog
Number
C400T1
C400T2
C400T12
C400T3
C400T4
C400T5
C400T9
C400T10
C400T11
C400T13
C400T14
C400T6
C400T15
C400T10
C400T16
PG03300001E
April 2008
Code
Letter
C
D