BZ-2R55-A2-S Honeywell, BZ-2R55-A2-S Datasheet - Page 64

no-image

BZ-2R55-A2-S

Manufacturer Part Number
BZ-2R55-A2-S
Description
Basic / Snap Action / Limit Switches Snap Action NO/NC SPDT 15A 4.17N
Manufacturer
Honeywell
Series
BZ seriesr
Type
Basicr
Datasheet

Specifications of BZ-2R55-A2-S

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Actuator Style
Pin Plunger
Current Rating (max)
15A
Terminal Type
Screw
Product Depth (mm)
17.5mm
Product Length (mm)
49.3mm
Operating Force
4.17N
Contact Form
SPDT
Contact Rating
15 Amps
Actuator
Plunger, Pin
Termination Style
Quick Connect
Lead Free Status / RoHS Status
Compliant
Basic Switches
Miniature Double-break
44
Honeywell Sensing and Control
Dim. Dwg. Fig. 1
Dim. Dwg. Fig. 2
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
ORDER GUIDE
1TB1-1
1TB1-2
1TB1-3
41TB5-3
Catalog
Listing
Two-circuit, double-
break end screw
terminals
Two-circuit, double-
break end solder
terminals
Two-circuit, double-
break front solder
terminals
Four-circuit, double-
break front solder
terminals
Description
FEATURES
10 amperes
Power load switching capability up to
Motor handling capacity of
power, 125 VAC
Two- and four-circuit double-break
Several auxiliary actuators
Choice of terminal styles
UL recognized, CSA certified
Momentary action
Electrical
Data And
UL Code
Page 20
10 Amps
10 Amps
10 Amps
10 Amps
Z
Z
Z
Z
Characteristics: O.F. – Operating Force; R.F. – Release Force;
P .T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P .
– Operating Position.
newtons
1,95-3,61
1,95-3,61
1,95-3,61
5,56-10,0
ounces
20-36
7-13
7-13
7-13
O.F.
For application help: call 1-800-537-6945.
1
2
R.F. min. P .T. max. O.T. min.
newtons
ounces
horse-
1,11
1,11
1,11
2,22
4
4
4
8
GENERAL INFORMATION
TB miniature switches are basic double-
break units which offer a means of con-
trolling isolated circuits. Each circuit can
be driven by independent voltage sourc-
es. These switches find many uses in
modern control systems because of their
circuitry.
The terminals of two- and four-circuit dou-
ble break switches must be wired to iden-
tical voltage sources and the same polar-
ity so that a voltage potential is not set up
between adjacent terminals. A voltage
potential between adjacent terminals
could promote dielectric breakdown at
high energy levels. The loads should be
on the same sides of the line.
inches
mm
.060
.060
.060
.070
1,52
1,52
1,52
1,78
inches
.010
.010
.010
.010
mm
0,25
0,25
0,25
0,25
.010-.025
.010-.025
.010-0.25
.025-.045
0,25-0,64
0,25-0,64
0,25-0,64
0,64-1,14
inches
D.T.
mm
TB Series
*
inches
O.P .**
.460
.460
.460
.185
mm
11,7
11,7
11,7
4,70
0,38 mm
.015 in

Related parts for BZ-2R55-A2-S