E2K-X4MY1 Omron, E2K-X4MY1 Datasheet

Proximity Sensor

E2K-X4MY1

Manufacturer Part Number
E2K-X4MY1
Description
Proximity Sensor
Manufacturer
Omron
Series
E2K-Xr
Type
Proximity Sensorr
Datasheets

Specifications of E2K-X4MY1

Proximity Sensor Type
Capacitive
Proximity Sensor Sensing Distance
4mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Ac Supply Voltage
90 to 250VAC
Ac Supply Voltage Range
90 to 245/>=245VAC
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Pin Count
3
Contact Current Max
200mA
Switch Terminals
Cable
Sensing Face Diameter
12mm
Supply Voltage Min
90VAC
Sensor Output
SCR, NO
Sensor Housing
Cylindrical
Sensor Input
Capacitive
Output Type
SCR
Maximum Operating Temperature
+ 70 C
Supply Voltage
12 VDC to 24 VDC
Supply Current
2.2 mA
Operating Supply Voltage
90 VAC to 250 VAC
Mounting Style
Panel
Sensing Distance
4 mm
Minimum Operating Temperature
- 25 C
Current Rating
200 mA
Features
Permits non-contact detection of metallic and non-metallic objects
Voltage Rating
200 VAC
Sensor Type
Capacitive
Sensing Object
Metallic and Non-Metallic
Response Frequency
10Hz
Material - Body
ABS Plastic
Shielding
Unshielded
Voltage - Supply
90 VAC ~ 250 VAC
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M12
Sensing Range Max
0.16"
Supply Voltage Max
250VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Compliant
General-purpose Threaded Sensor
That Detects Metals and Non-metals
Alike
■ Detects both metallic and nonmetallic objects (water, oil,
■ Three choices of threaded cylinder sizes for easy
■ Fixed sensing distance requires no sensitivity adjustment.
Ordering Information
Sensors
Accessories (Order Separately)
Mounting Brackets
Cylindrical Proximity Sensor
E2K-X
glass, plastic, etc.).
installation: M12, M18, and M30.
Unshielded
Be sure to read Safety Precautions on
page 5.
Appearance
http://www.ia.omron.com/
M12
M18
M30
Sensing distance
4 mm
8 mm
15 mm
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
AC 2-wire
Output configuration
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
E2K-X4ME1
E2K-X4MY1
E2K-X8ME1
E2K-X8MY1
E2K-X15ME1
E2K-X15MY1
NO
Operation mode
Model
E2K-X4ME2
E2K-X4MY2
E2K-X8ME2
E2K-X8MY2
E2K-X15ME2
E2K-X15MY2
NC
1

Related parts for E2K-X4MY1

E2K-X4MY1 Summary of contents

Page 1

... Accessories (Order Separately) Mounting Brackets http://www.ia.omron.com/ Output configuration DC 3-wire, NPN AC 2-wire DC 3-wire, NPN AC 2-wire DC 3-wire, NPN 2-wire (c)Copyright OMRON Corporation 2007 All Rights Reserved. Model Operation mode NO NC E2K-X4ME1 E2K-X4ME2 E2K-X4MY1 E2K-X4MY2 E2K-X8ME1 E2K-X8ME2 E2K-X8MY1 E2K-X8MY2 E2K-X15ME1 E2K-X15ME2 E2K-X15MY1 E2K-X15MY2 1 ...

Page 2

... E Models (DC switching models): A full-wave rectification power supply of 24 VDC 20% (average value) can be used. http://www.ia.omron.com/ E2K-X8ME@, E2K-X8MY 10 5 Refer to the timing charts under I/O Circuit Diagrams on page 4 for details times each and Z directions Approx. 145 g Instruction manual (c)Copyright OMRON Corporation 2007 All Rights Reserved. E2K-X E2K-X15ME@, E2K-X15MY 10 Operating/Storage (with no icing or condensation) Approx. 205 g 2 ...

Page 3

... Grounded metal plate 50 × 50 × E2K-X8M 6 4 E2K-X4M 2 0 −5 −20 −15 −10 − E2K-X4M Sensing Distance Y (mm) E2K-X8M Sensing Head E2K-X15M Sensing Head Influence of Sensing Object Size and Material E2K-X4M 5 d × Grounded metal 4 3 Non-grounded metal 2 1 Glass Phenol ...

Page 4

... E2K-X4ME2 and black leads) NC E2K-X8ME2 Output voltage (between E2K-X15ME2 black and blue leads) Detection indicator (red) AC 2-Wire Models Operation Model mode Sensing object E2K-X4MY1 NO E2K-X8MY1 Load E2K-X15MY1 Operation indicator (red) Sensing object E2K-X4MY2 NC E2K-X8MY2 Load E2K-X15MY2 Operation indicator (red) http://www.ia.omron.com/ ...

Page 5

... The maximum sensing distance of the E2K-X will be obtained if the object is made of grounded metal. There are objects that cannot be detected indirectly. Therefore, be sure to test the E2K trial operation with the objects before using the E2K-X in actual applications. Effects of a High-frequency Electromagnetic Field The E2K-X may malfunction if there is an ultrasonic washer, high- frequency generator, transceiver, or inverter nearby ...

Page 6

... OMRON Corporation 2007 All Rights Reserved. E2K-X (Unit: mm Indicator * 16.6 dia. *1 M18 × 1 Two clamping nuts Two washers 2 , Insulator diameter: 1.9 mm Insulator diameter: 1.9 mm), Model F (mm) E2K-X4ME@ +0.5 12.5 dia. 0 E2K-X4MY@ E2K-X8ME@ +0.5 18.5 dia. 0 E2K-X8MY@ E2K-X15ME@ +0.5 30.5 dia. E2K-X15MY ...

Page 7

... Brown − Sensor + Blue (c)Copyright OMRON Corporation 2007 All Rights Reserved. DC 2-Wire Sensors Load Brown Sensor Blue • DC 2-Wire Sensors • Even with the load short-circuit protection ...

Page 8

... Conduits, ducts, pre-wired, terminal wiring, ease of main- tenance and inspection mT* max. Do not use the Sensor at a level higher than 20 mT. Life: Power-ON time/frequency of use (c)Copyright OMRON Corporation 2007 All Rights Reserved. Peripheral metal Sensing distance Material, distance Fluctuation in tran- to Sensor, orien- sit point, allowable tation, etc ...

Page 9

... A Sensor is ready for detection within 100 ms after turning ON the power. If the load and Sensor are connected to separate power supplies, design the system so that the Sensor power turns ON first. (c)Copyright OMRON Corporation 2007 All Rights Reserved. Sensing object shape: Square d=30mm Reset ...

Page 10

... OFF It is recommend that leeway be included in the actual values used. For 12 VDC, use 15 kΩ or less and 450 mW or higher, and for 24 VDC, use 30 kΩ or less and 0 higher. (c)Copyright OMRON Corporation 2007 All Rights Reserved. AC power supply voltage Vs 2 (mW) ...

Page 11

... Loads with Large Inrush Current Loads, such as lamps or motors, that cause a large inrush weaken or damage the switching element. In this situation, use a relay. * E2K, TL-N@ higher ●Mounting Mounting the Sensor When mounting a Sensor, do not tap it with a hammer or otherwise subject it to excessive shock. This will weaken water resistance and may damage the Sensor ...

Page 12

... N: Number of Sensors that can be connected i: Leakage current of Proximity Sensor Example: When an MY (24-VDC) Relay is used as the load, the maximum number of Sensors that can be connected is 4. <TL-NY, TL-MY, E2K-@MY@, TL-T@Y> Load The above Proximity Sensors cannot be used in a sereis connection. If need- ed, connect through relays. ...

Page 13

... The residual voltage of the E2E-XD-M1J 3-Wire Sensors Operation can be reversed with the signal input switch on the S3D2. (c)Copyright OMRON Corporation 2007 All Rights Reserved. Description Example: A maximum of two Sensors can be used when an MY (24-VDC) Relay is used for the load ...

Page 14

... Do not under any circumstances attempt to disassemble or repair the product. Quick Failure Check You can conveniently check for failures by connecting the E39-VA Handy Checker to check the operation of the Sensor. http://www.ia.omron.com/ Proximity Sensors Technical Guide (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-8 ...

Page 15

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords