Datasheet

Specifications of MPX2202GP

Pressure Range
0 to 200KPa
Overload Pressure (max)
400KPa
Mounting
Through Hole
Pin Count
4
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Package Type
Case 344B-01
Operating Supply Voltage (typ)
10V
Operating Supply Voltage (max)
16V
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPX2202GP
Manufacturer:
LITEON
Quantity:
46 000
Part Number:
MPX2202GP
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPX2202GP
0
Sensors
Freescale Semiconductor
On-Chip Temperature Compensation and Calibration
series at 25°C. The output is directly proportional to the
differential pressure and is essentially a straight line.
chip carrier (Case 344). A silicone gel isolates the die surface
and wire bonds from the environment, while allowing the
pressure signal to be transmitted to the silicon diaphragm.
characteristics and internal reliability and qualification tests
are based on use of dry air as the pressure media. Media
other than dry air may have adverse effects on sensor
performance and long term reliability. Contact the factory for
information regarding media compatibility in your application.
the equation: V
pressure range. There are two basic methods for calculating
nonlinearity: (1) end point straight line fit (see
(2) a least squares best line fit. While a least squares fit gives
the “best case” linearity error (lower numerical value), the
calculations required are burdensome.
(often more desirable in error budget calculations) and the
calculations are more straightforward for the user.
Freescale’s specified pressure sensor linearities are based
on the end point straight line method measured at the
midrange pressure.
Figure 2
Figure 3
The MPX2202 series pressure sensor operating
Linearity refers to how well a transducer's output follows
Conversely, an end point fit will give the “worst case” error
Lead Frame
Wire Bond
Die Coat
Silicone Gel
shows the output characteristics of the MPX2202
illustrates the differential/gauge die in the basic
out
= V
off
Differential/Gauge
Die
LINEARITY
+ sensitivity x P over the operating
Differential/Gauge
PSI
kPa
P1
P2
40
35
30
25
20
15
10
-5
5
0
0
Figure 3. Cross Sectional Diagram (not to scale)
VS = 10 V
T
P1 > P2
Element
A
Figure 2. Output vs. Pressure Differential
= 25°C
25
Stainless Steel
Metal Cover
Figure
MAX
DC
7.25
50
4) or
75
Bond
Die
Epoxy
Case
TYP
14.5
Pressure
100
MIN
125
very small and are shown under Operating Characteristics.
Lead Frame
Wire Bond
The effects of temperature on full scale span and offset are
0
21.75
150
Exaggerated
Performance
Curve
Least Squares Fit
Figure 4. Linearity Specification Comparison
Silicone Gel
Die Coat
Offset
175
200
29
Pressure (% Full Scale)
Range
Span
(TYP)
Absolute
End Point Straight
Line Fit
Offset
Die
50
(TYP)
Absolute Element
P1
P2
Stainless Steel
Metal Cover
Pressure
100
Straight Line
Deviation
Least
Square
Deviation
Bond
MPX2202
Die
Epoxy
Case
5