ACS754LCB-100-PFF Allegro Microsystems Inc, ACS754LCB-100-PFF Datasheet - Page 7

SENSOR CURRENT 100A 5V BI 5-CB

ACS754LCB-100-PFF

Manufacturer Part Number
ACS754LCB-100-PFF
Description
SENSOR CURRENT 100A 5V BI 5-CB
Manufacturer
Allegro Microsystems Inc
Series
-r
Datasheet

Specifications of ACS754LCB-100-PFF

Magnetic Type
Monolithic
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.5V
Package Type
CB-PFF
Pin Count
5
Mounting
Through Hole
Operating Temp Range
-40C to 150C
Operating Temperature Classification
Automotive
Current - Sensing
±100A
Accuracy
±1.5%
Sensitivity
18 ~ 21.5 mV/A
Current - Supply
8mA
Sensor Type
Hall Effect
Voltage - Supply
4.5 V ~ 5.5 V
Output
2V
Frequency
35kHz
Response Time
11µs
Polarization
Bidirectional
Operating Temperature
-40°C ~ 150°C
Package / Case
5-CB Formed Leads
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS754LCB-100-PFF
Manufacturer:
TE/AMP
Quantity:
30 000
ACS754xCB-100
Definitions of Dynamic Response Characteristics
Response time (t
the primary current signal reaches 90% of its final value, and b)
when the device reaches 90% of its output corresponding to the
applied current.
Rise time (t
reaches 10% of its full scale value, and b) when it reaches 90%
of its full scale value. The rise time to a step response is used to
derive the bandwidth of the device, in which ƒ(–3 dB) = 0.35 / t
Both t
losses observed in the conductive IC ground plane.
Propagation delay (t
output to reflect a change in the primary current signal. Propaga-
tion delay is attributed to inductive loading within the linear IC
package, as well as in the inductive loop formed by the primary
conductor geometry. Propagation delay can be considered as a
fixed time offset and may be compensated.
r
and t
r
RESPONSE
). The time interval between a) when the device
RESPONSE
are detrimentally affected by eddy current
PROP
). The time interval between a) when
). The time required for the device
–I
with High Voltage Isolation and a Low-Resistance Current Conductor
P
(A)
I
Output Voltage versus Sampled Current
P
(min)
Accuracy at 0 A and at Full-Scale Current
Fully Integrated, Hall Effect-Based Linear Current Sensor IC
O e
O e
Accuracy
v r
v r
Temp erature
Accuracy
25°C Only
Temp erature
25°C Only
Accuracy
Accuracy
r
.
0 A
Increasing V
Decreasing V
Average
V
IOUT
IOUT
Accuracy
25°C Only
IOUT
(V)
(V)
Full Scale
I (%)
I (%)
I (%)
90
90
90
10
I
0
0
0
P
(max)
O e
Accuracy
v r
Propagation Time, t
+I
Temp erature
P
(A)
115 Northeast Cutoff
1.508.853.5000; www.allegromicro.com
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 U.S.A.
Primary Current
Primary Current
Primary Current
Response Time, t
Rise Time, t
Transducer Output
Transducer Output
Transducer Output
PROP
r
RESPONSE
t
t
t
6

Related parts for ACS754LCB-100-PFF