GP1F33RT Sharp Electronics, GP1F33RT Datasheet - Page 5

no-image

GP1F33RT

Manufacturer Part Number
GP1F33RT
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of GP1F33RT

Optical Fiber Type
TX/RX
Data Transfer Rate
8Mbps
Optical Rise Time
30ns
Optical Fall Time
30ns
Jitter
1ns
Operating Temperature Classification
Commercial
Peak Wavelength
660/700nm
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
-20C to 70C
Mounting
Snap Fit
Pin Count
3
Lead Free Status / RoHS Status
Not Compliant
Fig.3 Pulse Response Measuring Method
Fig.4 Measuring Method of Jitter
Input signal
Standard receiver
output
Input
Input
Input signal
GP1F31T/GP1F32T
GP1F33TT/GP1F33RT
Input signal
(CH1)
Standard receiver
Output signal
(CH2)
GP1F31T/GP1F32T/
GP1F33TT/GP1F33RT
Unit to be measured
1 1 0
V
in
GP1F31T/GP1F32T/
GP1F33TT/GP1F33RT
Unit to be measured
V
in
V
Pulse width distortion
CC
0
V
6Mbps NRZ “1010” successive pattern
CC
V
GND
GP1F31T/R, GP1F32T/R, GP1F33TT/RR/RT, GP1C331/331A/332/333/334/335
CC
Input signal 3Mbps
biphase mark PRBS signal
t
V
GND
PLH
tj
CC
tj
tw t
t
PHL
PHL
Standard optical fiber cable
50%
50%
Standard optical fiber cable
t
PLH
50%
50%
Notes (1) The waveform write time shall be 4 seconds. But do
(2) V
(3) The probe for the oscilloscope must be more than
not allow the waveform to be distorted by increasing
the brightness too much.
1M and less than 10pF.
CH1
CH2
CC
CH1
CH2
Oscilloscope
5.0 0.05V (Operating)
Notes (1) V
(2) The probe for the oscilloscope must be
more than 1M and less than 10pF.
CC
5.0 0.05V (Operating)
Oscilloscope
Trigger : CH1 Storage mode
Output
signal
Standard
receiver
Standard
receiver
Output
signal