FN660-16-06 Schaffner EMC Inc, FN660-16-06 Datasheet - Page 43

FILTER 2-STAGE GENERAL 16A

FN660-16-06

Manufacturer Part Number
FN660-16-06
Description
FILTER 2-STAGE GENERAL 16A
Manufacturer
Schaffner EMC Inc
Series
FN 660r
Datasheets

Specifications of FN660-16-06

Filter Type
Power Line
Mounting Type
Chassis Mount
Voltage - Rated
250V
Current
16A
Inductance
440µH
Termination Style
Fast-On
Current Rating
16A
Voltage Rating
250VAC
Leakage Current Max
190µA
Capacitance
0.15µF
Inductance Min
440µH
Terminal Type
Quick Connect
Mounting Style
SMD/SMT
Frequency
60 Hz
Leakage Current
190 uA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
282-354
817-1221
FN 660 -16 /06
Additional specifications
MTBF at 40°C, 230V, per Mil-HB-217F: 350,000 hours (for VDE-approved current ratings).
Two-stage general-purpose filter
Filter selection table
Choose the family FN xxx with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 660-3/07 is a 3A
filter with wire connections.
Like the FN 612, but with an additional inductance stage for higher
common mode attenuation, this family is designed to provide an
economic solution for many general-purpose filtering requirements.
Available in 14 versions, with current ratings from 1 to 20A and with a
choice of four different styles of connection, application requirements are
easily and economically matched.
Filter type
Family
FN 660 -1
FN 660 -3
FN 660 -6
FN 660 -10 /??
FN 660 -16 /??
FN 660 -20 /??
Standard types
B types (medical)
42
optional medical versions (B type)
current ratings from 1 to 20A
high differential and common mode attenuation
four choices of output connector
/??
/??
/??
/03
/03
-
-
-
-
Connections
/06
/06
/06
/06
/06
/06
150
150
Cx
nF
Capacitance
/07
/07
/07
/07
-
-
2.2
Cy
nF
-
/10
/10
-
-
-
-
Res.
M
R
1
1
A at 40°C (25°)
Current ratings
10
16
20
1
3
6
µ
Maximum
A/phase
leakage
190
(1.15)
(11.5)
(18.4)
(3.4)
(6.9)
(23)
2
operating voltage
Inductance
0.75/0.75
0.45/0.45
0.44/0.44
0.48/0.48
VAC
250 50/60
250 50/60
Maximum
L
mH
3/3
2/2
/
L
1
Hz
Housing
FN 660
See Mechanical Data (pages 57, 58 and 60)
for full details of housings and connections.
Approvals
(16A max. for VDE)
H21
K21
D
K1
K1
K2
L1
SCHAFFNER
V
E
DC to 400
DC to 400
Operating
frequency
290
600
/03
Hz
-
-
-
-
115
170
170
230
260
590
/06
Weight
Hipot test voltage
PN E
g
2000
2500
VAC
125
180
180
240
/07
-
-
P N
1700
1700
VAC
290
640
/10
-
-
-
-

Related parts for FN660-16-06