5962-8760801QZA National Semiconductor, 5962-8760801QZA Datasheet
5962-8760801QZA
Specifications of 5962-8760801QZA
Related parts for 5962-8760801QZA
5962-8760801QZA Summary of contents
Page 1
... Typical Connection and Performance Curve Functional Diagram © 2000 National Semiconductor Corporation Features n Operates from n Less than 10 µs acquisition time n TTL, PMOS, CMOS compatible logic input n 0 ...
Page 2
... Absolute Maximum Ratings If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage Power Dissipation (Package Limitation) (Note 2) Operating Ambient Temperature Range LF198/LF198A LF298 LF398/LF398A Storage Temperature Range Input Voltage Logic To Logic Reference ...
Page 3
... Note 7: Leakage current is measured at a junction temperature of 25˚C. The effects of junction temperature rise due to power dissipation or elevated ambient can be calculated by doubling the 25˚C value for each 11˚C increase in chip temperature. Leakage is guaranteed over full input signal range. Note 8: A military RETS electrical test specification is available on request. The LF198 may also be procured to Standard Military Drawing # 5962-8760801GA or to MIL-STD-38510 part ID JM38510/12501SGA. ...
Page 4
Typical Performance Characteristics Output Droop Rate DS005692-20 Leakage Current into Hold Capacitor DS005692-23 Power Supply Rejection DS005692-26 Note 10: See Definition www.national.com (Continued) Hold Step DS005692-21 Phase and Gain (Input to Output, Small Signal) DS005692-24 Output Short Circuit Current DS005692-27 ...
Page 5
Typical Performance Characteristics Input Bias Current DS005692-29 Output Transient at Start of Sample Mode Logic Input Configurations DS005692-33 Threshold = 1.4V (Continued) Feedthrough Rejection Ratio (Hold Mode) DS005692-30 Output Transient at Start of Hold Mode DS005692-12 TTL & CMOS 3V ...
Page 6
Logic Input Configurations + Threshold = 0 1.4V Threshold +4V Application Hints Hold Capacitor Hold step, acquisition time, and droop rate are the major trade-offs in the selection of a hold capacitor value. Size and cost may ...
Page 7
Application Hints (Continued) logic input for signal delay, calculate the slope of the wave- form at the threshold point to ensure that least 1.0 V/µs. Sampling Dynamic Signals Sample error to moving input signals probably causes more ...
Page 8
Typical Applications X1000 Sample & Hold * For lower gains, the LM108 must be frequency compensated Ramp Generator with Variable Reset Level www.national.com V OUT DS005692-39 Integrator with Programmable Reset Level DS005692-42 8 Sample and Difference Circuit (Output Follows Input ...
Page 9
Typical Applications (Continued) Output Holds at Average of Sampled Input Reset Stabilized Amplifier (Gain of 1000) DS005692-46 Fast Acquisition, Low Droop Sample & Hold DS005692-49 9 Increased Slew Current DS005692-47 DS005692-50 www.national.com ...
Page 10
Typical Applications (Continued) Synchronous Correlator for Recovering Signals Below Noise Level DC & AC Zeroing www.national.com DS005692-52 Staircase Generator DS005692-59 * Select for step height 50k 1V Step 10 2–Channel Switch DS005692- ± ± Gain 1 0.02% 1 ...
Page 11
Typical Applications (Continued) Differential Hold Definition of Terms Hold Step: The voltage step at the output of the sample and hold when switching from sample mode to hold mode with a steady (dc) analog input voltage. Logic swing is 5V. ...
Page 12
Physical Dimensions Order Number LF198H, LF298H, LF398H, LF198AH or LF398AH www.national.com inches (millimeters) unless otherwise noted Metal Can Package (H) NS Package Number H08C Molded Small-Outline Package (M) Order Number LF298M or LF398M NS Package Number M14A 12 ...
Page 13
... NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant ...