H3DK-M1 AC/DC24-240 Omron, H3DK-M1 AC/DC24-240 Datasheet - Page 26

no-image

H3DK-M1 AC/DC24-240

Manufacturer Part Number
H3DK-M1 AC/DC24-240
Description
TIMER, MULTIFUNCTION, 5A, 24-240AC/DC
Manufacturer
Omron
Datasheet

Specifications of H3DK-M1 AC/DC24-240

Contact Configuration
SPDT
Delay Time Range
0.1s To 1200h
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Adjustment Type
Screwdriver Slot
Contact Current Ac Max
5A
Contact Current Dc
RoHS Compliant
Supply Voltage Range
24VAC To 240VAC / 24VDC To 240VDC
Time Range
0.1sec To 1200hr
Rohs Compliant
Yes
26
H3DK
● Changing Switch Settings
Do not change the time unit, time scale, operating mode, or INIT/
TIME switch while the Timer is in operation. Doing so may result
in malfunction. Turn OFF the power supply before changing the
setting of any switch.
● Mounting and Dismounting
● Power Supply
• Although there are no particular mounting restrictions, the
• When mounting the Timer on a mounting Track, loosen the
• When removing the Timer, pull out the two hooks, and then
• It will be easier to mount and dismount the Timer if a distance
• The power supply can be connected to the power input termi-
• A DC power supply can be connected if its ripple factor is 20%
• For the power supply of the input device, use an isolating
• The H3DK-H has a large inrush current. Provide sufficient
Timer should be mounted as horizontally as possible.
two hooks, press the Timer onto the Track, and then insert the
hooks.
remove the Timer from the Track
of 30 mm or more is provided between the bottom of the Timer
and other equipment.
nals without considering polarity.
or less and the average voltage is within the allowable voltage
fluctuation range of the Timer.
transformer in which the primary and secondary windings are
mutually isolated and the secondary winding is not grounded.
(H3DK-M1 and H3DK-M2 only)
power supply capacity.
If the power supply capacity is too small, there may be delays
in turning ON the output.
Precautions for Correct Use
Start
input
Circuit
B1
Isolation transformer is required.
H3DK
A1
A2
Hook
Hook
Hook
Hook
30 mm min.
Power
● Relationship between Input and Power Supply Cir-
● Environment
• The input circuit and the power supply circuit are configured
• If a relay or transistor is connected to two or more Timers, the
• When using the Timer in an area with excessive electronic
• The external impulse voltage entering across the power supply
independently. The input circuit can be turned ON and OFF
without considering the ON/OFF state of the power supply.
A voltage equivalent to the power supply voltage is also
applied to the input circuit.
input terminals of those Timers must be wired properly so that
they will not be different in phase or the terminals will be short-
circuited to one another. Always use the same power supply
phases.
noise, separate the Timer and input device as far as possible
from the noise sources. It is also recommended to shield the
input signal wiring to prevent electronic interference.
terminals has been checked against a ±1.2×50 µs standard
waveform according to JEC-210, Impulse Voltage/Current
Test, of The Institute of Electrical Engineers of Japan. Surge
or noise superimposed on the power supply may damage
internal components or cause them to malfunction. We recom-
mend that you check the circuit waveform and use surge
absorbers. The effects on components depend on the type of
surge and noise that are generated. Always perform testing
with the actual equipment.
cuits (H3DK-M1/-M2)
Contact or transistor for
external input signal
Contact or transistor for
external input signal
power supply
AC/DC
B1
B1
B1
B1
Input circuit
H3DK
H3DK
H3DK
H3DK
A1
A2
A1
A2
A1
A2
A1
A2
B1
A2
Power supply circuit
A1
Power
Power

Related parts for H3DK-M1 AC/DC24-240