SPX29301T5-L-5-0 Exar Corporation, SPX29301T5-L-5-0 Datasheet
SPX29301T5-L-5-0
Specifications of SPX29301T5-L-5-0
Available stocks
Related parts for SPX29301T5-L-5-0
SPX29301T5-L-5-0 Summary of contents
Page 1
... The SPX29300 is offered in a 3-pin TO-263 package, the SPX29301 is offered in a 5-pin TO-263 while SPX29302 is offered in a 5-pin TO-263 and 5-pin TO-220 packages. TYPICAL APPLICATION DIAGRAM Fig. 1: SPX29300 and SPX29302 Application Diagrams Exar Corporation 48720 Kato Road, Fremont CA 94538, USA ...
Page 2
... Ground Pin Current at Dropout Current Limit 3.0 Output Noise Voltage Reference Voltage Temperature Coefficient Reference Voltage and Adjustable Pin - SPX29302 1.228 1.215 Reference Voltage 1.203 Adjust Pin Bias Current Adjust Pin Bias Current Temperature Coefficient © 2010 Exar Corporation OPERATING RATINGS Input Voltage Range V Junction Temperature Range .................... -40° ...
Page 3
... Threshold remain constant as a percent varied, with the dropout warning occurring at typically 5% below nominal, 7.7% guaranteed. OUT OUT Note 9: V ≤ 0.8V and V ≤ 16V BLOCK DIAGRAM © 2010 Exar Corporation Typ. Max. Units 0.01 1 µA 2 ...
Page 4
... J SPX29301T5-L-3-3 -40°C≤T ≤+125°C J SPX29301T5-L-3-3/TR -40°C≤T ≤+125°C J SPX29301T5-L-5-0 -40°C≤T ≤+125°C J SPX29301T5-L-5-0/TR -40°C≤T ≤+125°C J SPX29302T5-L -40°C≤T ≤+125°C J SPX29302T5-L/TR -40°C≤T ≤+125°C J SPX29302U5-L -40°C≤T ≤ ...
Page 5
... TYPICAL PERFORMANCE CHARACTERISTICS All data taken 1V OUT J Fig. 4: Dropout Voltage vs Load Current Fig. 6: Line Regulation I =10mA, V OUT OUT © 2010 Exar Corporation 25°C, unless otherwise specified. A =3.3V 5/ Fig. 5: Startup Fig. 7: Load Regulation V =3.3V OUT / Rev. 2.1.0 ...
Page 6
... R APACITOR EQUIREMENTS The output capacitor is needed to insure stability and minimize the output noise. The value of the capacitor varies with the load. However, a minimum value of 10μF aluminum © 2010 Exar Corporation capacitor will guarantee stability over all load conditions. A tantalum capacitor is recommended if a faster load transient response is needed. If the power source has high AC impedance, a 0.1μ ...
Page 7
... PACKAGE SPECIFICATION 3-P TO-263 IN © 2010 Exar Corporation 7/ Rev. 2.1.0 ...
Page 8
... TO-263 IN © 2010 Exar Corporation 8/ Rev. 2.1.0 ...
Page 9
... TO-220 IN © 2010 Exar Corporation 9/ Rev. 2.1.0 ...
Page 10
... While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized ...