PIC16F882-E/SS Microchip Technology, PIC16F882-E/SS Datasheet - Page 11

no-image

PIC16F882-E/SS

Manufacturer Part Number
PIC16F882-E/SS
Description
IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,SSOP,28PIN,PLASTIC
Manufacturer
Microchip Technology
Series
PIC® 16Fr

Specifications of PIC16F882-E/SS

Core Processor
PIC
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
3.5KB (2K x 14)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
28-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
9. Module: LP/Timer1 Oscillator Operation
10. Module: Timer0 and WDT Prescaler
© 2009 Microchip Technology Inc.
1-2% of devices experience reduced drive as
temperatures approach -40°C. This will result in a
loss of Timer1 counts or stopped Timer1
oscillation.
This can also prevent Timer1 oscillator start-up
under cold conditions.
Work around
Use of low-power crystals properly matched to the
device will reduce the likelyhood of failure. A 1mΩ
resister between OSC2 and V
improve the drive strength of the circuit.
Affected Silicon Revisions
PIC16F882
PIC16F883/PIC16F884
PIC16F886/PIC16F887
A spurious Reset may occur if the Timer0/
Watchdog Timer (WDT) prescaler is assigned
from the WDT to Timer0 and then back to the
WDT.
Summary
The issue only arises when all of the below
conditions are met:
• Timer0 external clock input (TOCKI) is enabled.
• The Prescaler is assigned to the WDT, then to
• During the assignments, the T0CKI pin is high
• The 1:1 Prescaler option is chosen.
A0
A0
A2
X
X
X
the Timer0 and back to the WDT.
when bit TOSE is set, or low when TOSE is
clear.
Below 25°C
Assignment Spurious Reset
DD
will further
Description
On a POR, the Timer0/WDT prescaler is assigned
to the WDT.
If the prescaler is reassigned to Timer0 and
Timer0 external clock input (TOCKI) is enabled
then the prescaler would be clocked by a transition
on the TOCKI pin.
On power-up, the TOCKI pin is (by default)
enabled for Timer0 in the OPTION register.
If the T0CKI pin is:
• High and Timer0 is configured to transition on a
• Low and Timer0 is configured to transition on a
Then, if the prescaler is reassigned to the WDT, a
clock pulse to the prescaler will be generated on
the reassignment.
If the prescaler is configured for the 1:1 option, the
clock pulse will incorrectly cause a WDT Time-out
Reset of the device.
Work around
2.
3.
Affected Silicon Revisions
PIC16F882
PIC16F883/PIC16F884
PIC16F886/PIC16F887
1.
A0
A0
A2
falling edge (TOSE set), or
rising edge (TOSE clear)
X
X
X
Disable the Timer0 external clock input by
clearing the TOCKI bit in the OPTION
register.
Modify the TOSE bit in the OPTION register to
the opposite configuration for the logic level
on the T0CKI pin.
Select a prescaler rate other than 1:1 and
issue a CLRWDT instruction before switching
to the final prescaler rate.
PIC16F88X