HC55185AIM Intersil, HC55185AIM Datasheet - Page 10

HC55185AIM

Manufacturer Part Number
HC55185AIM
Description
Manufacturer
Intersil
Datasheet

Specifications of HC55185AIM

Number Of Channels
1
On-hook Transmission
Yes
Polarity Reversal
Yes
On-chip Ring Relay Driver
Yes
Longitudinal Balanced
67
Operating Supply Voltage (typ)
5/-18/-24/-28V
Operating Temp Range
-40C to 85C
Package Type
PLCC
Loop Current Limit
45mA
Operating Temperature Classification
Industrial
Pin Count
28
Mounting
Surface Mount
Operating Current
10.3mA
Operating Supply Voltage (max)
5.25/-52V
Operating Supply Voltage (min)
4.75/-16V
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HC55185AIM
Manufacturer:
HARRIS
Quantity:
16
Part Number:
HC55185AIM
Manufacturer:
INTERISL
Quantity:
4 154
Part Number:
HC55185AIM
Manufacturer:
HINTESIL
Quantity:
20 000
Part Number:
HC55185AIM96
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
HC55185AIMZ
Manufacturer:
INTERSIL
Quantity:
7 144
Part Number:
HC55185AIMZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
HC55185AIMZ96
Manufacturer:
INTERSIL
Quantity:
6 792
Low Power Standby
Overview
The low power standby mode (LPS, 000) should be used
during idle line conditions. The device is designed to operate
from the high battery during this mode. Most of the internal
circuitry is powered down, resulting in low power dissipation.
If the 2-wire (tip/ring) DC voltage requirements are not
critical during idle line conditions, the device may be
operated from the low battery. Operation from the low battery
will decrease the standby power dissipation.
2-Wire Interface
During LPS, the 2-wire interface is maintained with internal
switches and voltage references. The Tip and Ring
amplifiers are turned off to conserve power. The device will
provide MTU compliance, loop current and loop supervision.
Figure 3 represents the internal circuitry providing the 2-wire
interface during low power standby.
MTU Compliance
Maintenance Termination Unit or MTU compliance places
DC voltage requirements on the 2-wire terminals during idle
line conditions. The minimum idle voltage is 42.75V. The
high side of the MTU range is 56V. The voltage is expressed
as the difference between Tip and Ring.
The Tip voltage is held near ground through a 600Ω resistor
and switch. The Ring voltage is limited to a maximum of
-56V (by MTU REF) when operating from either the high or
low battery. A switch and 600Ω resistor connect the MTU
reference to the Ring terminal. When the high battery
Receive
Ringing
Transmit
2-Wire
Loop Detect
INTERFACE
FIGURE 3. LPS 2-WIRE INTERFACE CIRCUIT DIAGRAM
TABLE 3. DEVICE INTERFACES DURING LPS
RING
ON
TIP
x
x
MTU REF
OFF
GND
x
x
x
10
600Ω
600Ω
AC transmission, impedance
matching and ringing are
disabled during this mode.
Amplifiers disabled.
Switch hook or ground key.
TIP AMP
RING AMP
NOTES
HC55185
voltage exceeds the MTU reference of -56V, the Ring
terminal will be clamped by the internal reference (typically
-54V). The same Ring relationships apply when operating
from the low battery voltage. For high battery voltages (V
less than or equal to the internal MTU reference threshold:
Loop Current
During LPS, the device will provide current to a load. The
current path is through resistors and switches, and will be
function of the off hook loop resistance (R
includes the off hook phone resistance and copper loop
resistance. The current available during LPS is determined
by Equation 15.
Internal current limiting of the standby switches will limit the
maximum current to 20mA.
Another loop current related parameter is longitudinal
current capability. The longitudinal current capability is
reduced to 10mA
current capability is a result of turning off the Tip and Ring
amplifiers.
On Hook Power Dissipation
The on hook power dissipation of the device during LPS is
determined by the operating voltages and quiescent currents
and is calculated using Equation 16.
The quiescent current terms are specified in the electrical
tables for each operating mode. Load power dissipation is
not a factor since this is an on hook mode. Some
applications may specify a standby current. The standby
current may be a charging current required for modern
telephone electronics.
Standby Current Power Dissipation
Any standby line current, I
power dissipation term P
power contribution is zero when the standby line current is
zero.
If the battery voltage is less than -49V (the MTU clamp is
off), the standby line current power contribution reduces to
Equation 18.
Most applications do not specify charging current
requirements during standby. When specified, the typical
charging current may be as high as 5mA.
V
I
P
P
P
LOOP
RING
LPS
SLC
SLC
=
=
=
=
=
V
I
I
SLC
SLC
BH
(
V
BH
1
×
×
×
I
(
(
+
BHQ
– (
V
V
4
49
BH
BH
RMS
+
)
)
V
+
(
BL
49
per pin. The reduction in longitudinal
1
600
+
SLC
+
×
I
SLC
SLC
I
1
+
BLQ
+
600
. Equation 17 illustrates the
I
x1200
, introduces an additional
SLC
+
+
V
R
x1200
CC
LOOP
)
×
I
CCQ
)
)
LOOP
December 18, 2006
). This
(EQ. 14)
(EQ. 15)
(EQ. 16)
(EQ. 17)
(EQ. 18)
FN4831.14
BH
)