Specifications of 19699-002-XTP

Number Of Transmitters
1
Power Supply Requirement
Dual
Package Type
LQFP
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
44
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Lead Free Status / RoHS Status
Compliant
AMIS-49200
4.4.2. Receive Signal Detection
The carrier detector generates the receive activity (RxA) signal by detecting the input signal amplitude. Minimum amplitude is 100mVp-
p (TYP). A delay, determined by the capacitor connected between the CCD pin and GND, is added to avoid detection of transient
noise. The recommended value of C
The zero-cross detector generates the receive signal (RxS) with minimum phase error (jitter) by detecting the transition between high
and low levels of the incoming Manchester code. Hysteresis of +40mV (TYP) is applied to avoid unnecessary switching by noise.
Once the carrier-detect goes active the hysteresis is removed and the switching point threshold is set to Vmid. The output can drive a
CMOS input of V
DD
supply voltage.
Detectors
35
34
CCD
32
RXA
RXS
To
Convert
Level
Convert
VDD
Level
VDD
31
FLTOUT
CD
CD_Output
VCC
is 100pF. The output can drive a CMOS input of V
VCC
A2
VCC
C3=220pf
C1
29
Carrier Detector
C4=47pf
ZC Tript Pt
Rev. 5 | Page 17 of 22 | www.onsemi.com
RF4
54K
Figure 12: Receive Signal Detectors
30
Figure 11: Band Pass Filter
VCC
VCC
FLT
Vtrip = Vmid
Vhyst = + 40mV
RF3
20K
Zero-Cross Detector
C2
C2
VHi50
VLo50
VCC
A1
RF1
75K
Bandpass Filter
270K
RF2
RxSig
VHi50 = Vmid + 50mV
VLo50 = Vmid - 50mV
Vmid
HPF
SIGIN
28
27
R
(1Meg)
Vmid
(60pF)
DD
1000pf
C
C2
supply voltage.
Filtered received signal
from Bandpass Filter
1000pf
C1
Signal
Input