TJA1055T/3,512 NXP Semiconductors, TJA1055T/3,512 Datasheet - Page 4

TJA1055T/3,512

Manufacturer Part Number
TJA1055T/3,512
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of TJA1055T/3,512

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Standard Supported
TJA1054
Operating Supply Voltage (max)
5.25/40V
Operating Supply Voltage (typ)
5/9/12/15/18/24/28V
Operating Supply Voltage (min)
4.75/5V
Package Type
SO
Supply Current
0.22/21mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
14
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
6. Pinning information
TJA1055_4
Product data sheet
6.1 Pinning
6.2 Pin description
Table 3.
Symbol
INH
TXD
RXD
ERR
STB
EN
WAKE
RTH
RTL
V
CANH
CANL
GND
BAT
Fig 2.
CC
Pin configuration
Pin description
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Rev. 04 — 17 February 2009
Description
inhibit output for switching an external voltage regulator if a
wake-up signal occurs
transmit data input for activating the driver to the bus lines
receive data output for reading out the data from the bus lines
error, wake-up and power-on indication output; active LOW in
normal operating mode when a bus failure is detected; active LOW
in standby and sleep mode when a wake-up is detected; active
LOW in power-on standby when a V
standby digital control signal input; together with the input signal
on pin EN this input determines the state of the transceiver;
see
enable digital control signal input; together with the input signal on
pin STB this input determines the state of the transceiver;
see
local wake-up signal input (active LOW); both falling and rising
edges are detected
termination resistor connection; in case of a CANH bus wire error
the line is terminated with a predefined impedance
termination resistor connection; in case of a CANL bus wire error
the line is terminated with a predefined impedance
supply voltage
HIGH-level CAN bus line
LOW-level CAN bus line
ground
battery supply voltage
WAKE
RXD
ERR
TXD
STB
INH
EN
Table 5
Table 5
1
2
3
4
5
6
7
and
and
TJA1055T/3
TJA1055T
Figure 3
Figure 3
001aac770
Enhanced fault-tolerant CAN transceiver
14
13
12
11
10
9
8
BAT
GND
CANL
CANH
V
RTL
RTH
CC
BAT
power-on event is detected
© NXP B.V. 2009. All rights reserved.
TJA1055
4 of 26

Related parts for TJA1055T/3,512