MCZ33742SEG Freescale, MCZ33742SEG Datasheet - Page 33

MCZ33742SEG

Manufacturer Part Number
MCZ33742SEG
Description
Manufacturer
Freescale
Datasheet

Specifications of MCZ33742SEG

Data Rate
1000Kbps
Number Of Transceivers
1
Standard Supported
CAN 2.0
Operating Supply Voltage (max)
27V
Operating Supply Voltage (typ)
5/9/12/15/18/24V
Operating Supply Voltage (min)
4.5V
Package Type
SOIC W
Supply Current
45mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
28
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33742SEG
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MCZ33742SEG
Manufacturer:
FREESCALE
Quantity:
285
Part Number:
MCZ33742SEG
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MCZ33742SEGR2
Manufacturer:
HARRIS
Quantity:
2 381
Part Number:
MCZ33742SEGR2
Manufacturer:
FREESCALE
Quantity:
480
Analog Integrated Circuit Device Data
Freescale Semiconductor
Notes
43.
44.
1
State Machine Description
Nostop = Nostop bit = 1
! Nostop = Nostop bit = 0
BATFAIL = Batfail bit = 1
! BATFAIL = Batfail bit = 0
V
V
V
Watchdog: Trigger = TIM1 subregister write operation
V
DD
DD
DD
SUP
These two SPI commands must be sent consecutively in this sequence.
If watchdog activated.
2
Over-temperature = V
LOW = V
LOW > 100 ms = V
> BFew = V
Power
Down
3
Power-Up
Request
Normal
Normal
Trigger
Reset
DD
4
Reset
Yes
below reset threshold
SUP
Denotes priority
> Battery Fail Early Warning (6.1 V typical)
DD
(V
DD
No
DD
below reset threshold for more than 100 ms
High Temperature OR [V
thermal shutdown occurs
Reset Counter (3.4 ms)
Figure 13. SBC State Diagram (Not Valid in Debug Modes)
Batfail
Expired
Yes
Timeout 350 ms & Nostop
V
DD
Figure 14. Operation After SBC Power-Up
Low OR Watchdog:
Watchdog: Timeout OR V
No
DD
Low > 100 ms & V
1
Watchdog: Timeout OR V
1
No Stop
Normal Request
Wake-Up
No
Stop
2
Watchdog: Timeout & Nostop &!BATFAIL
2
DD
SUP
Yes
Watchdog: Timeout = TIM1 register not written before watchdog timeout period
SPI: Sleep = SPI write command to MCR register, data sleep
SPI: Stop = SPI write command to MCR register, data stop
SPI: Normal = SPI write command to MCR register, data normal
SPI: Standby = SPI write command to MCR register, data standby
Low
expired, or watchdog written in incorrect time window if watchdog window
selected (except Stop mode). In Normal Request mode, timeout is 355 ms
p2.2 (350 ms p3) ms.
> BFew]) & Nostop &!BATFAIL
4
Operation after power-up if no trigger appears
Operation after reset of BATFAIL if no trigger appears
DD
Low
SPI: Stop & CS
LOW to HIGH
Sleep
Transition
Watchdog Trigger
SPI: Standby and
3
Normal
Standby
FUNCTIONAL DEVICE OPERATION
1
1
OPERATIONAL MODES
Sleep
33742
33

Related parts for MCZ33742SEG