PM4HW-H-DC12VSW Panasonic Electric Works, PM4HW-H-DC12VSW Datasheet

no-image

PM4HW-H-DC12VSW

Manufacturer Part Number
PM4HW-H-DC12VSW
Description
Manufacturer
Panasonic Electric Works
Datasheet

Specifications of PM4HW-H-DC12VSW

Lead Free Status / RoHS Status
Compliant
Specifications
Notes:
PM4H-W
Item
Rating
Time
accuracy
Contact
Life
Electrical
function
Mechanical
function
Operating
condition
Other
50
1.890
Note:1)
48
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% rip-
2) For the 1s range, the tolerance for each specification becomes ±10ms.
3) As internal components may become worn when using continuous conduction, the product should be replaced periodically.
ple factor for DC), 20°C
Rated operating voltage
Rated frequency
Rated power con umption
Rated control capacity
Operation mode
Time range
Operation time fluctuation
Setting error
Voltage error
Temperature error
Contact arrangement
Contact re i tance (Initial value)
Contact material
Mechanical (contact)
Electrical (contact)
Allowable operating voltage range
In ulation re i tance (Initial value)
Breakdown voltage (Initial value)
Min. power off time
Max. temperature ri e
Vibration re i tance
Shock re i tance
Ambient temperature
Ambient humidity
Atmo pheric pre
Ripple factor (DC type)
Protective con truction
Weight
1.890
48
ure
68°F
Functional
De tructive
Functional
De tructive
62.5
2.461
mm
ambient temperature, and 1s power off time.
inch
Type
ANALOG MULTI-RANGE
UL File No.: E122222
CSA File No.: LR39291
Features
• A single twin timer unit that repeats (variable) ON/OFF.
• Multiple ranges with a 0.1 s to 500 h time specification on a single unit.
• The output ON/OFF operation is indicated by red and green LED’s.
• The AC free power supply and shorter body make it easier to use.
• A new screw terminal type has been added to the conventional pin type. Wiring
• Compliant with UL, CSA, CE and LLOYD.
It’s easy to check the operation at a glance.
can be done easily with a screwdriver.
CYCLIC TWIN TIMERS
DIN48 SIZE
IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
2% (at 20 C ambient temp. at the range of –10 to +50 C
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
1s to 500h 16 time ranges switchable (T
09/2009
Min. 100M
120g
0.5% (at the operating voltage changes between 85 to 110%)
85 to 110% of rated operating voltage (at 20 C coil temp.)
2,000Vrms for 1 min Between live and metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole
100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DC
0.3% (power off time change at the range of 0.3s to 1h)
4.233 oz
Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC)
50/60Hz common (AC operating type)
Between live and dead metal parts
Between input and output
Between contacts of different poles
Between contacts of same pole
Cyclic (OFF-start/Twin operation)
Min. 980m/s
(Pin type), 130g
Approx. 10VA (100 to 240V AC)
Min. 98m/s
30 to 85%RH (non-condensing)
10
–10 to +50 C
5A 250V AC (resistive load)
Max. 100m (at 1A 6V DC)
5
Approx. 2.5VA (24V AC)
(at rated control capacity)
Timed-out 2 Form C
5% (Full-scale value)
860 to 1,060hPa
55 C
Silver alloy
2
PM4H-W
2
300ms
(4 times on 3 axes)
2 10
(5 times on 3 axes)
20%
131 F
+14 to +122 F
4.586 oz
7
1
, T
2
(Screw terminal type)
time setting individually)
PM4H-W
(At 500V DC)
+14 to 122
F)

Related parts for PM4HW-H-DC12VSW

PM4HW-H-DC12VSW Summary of contents

Page 1

PM4H-W 48 1.890 62.5 48 2.461 1.890 mm inch Specifications Type Item Rated operating voltage Rated frequency Rated power con umption Rating Rated control capacity Operation mode Time range Operation time fluctuation Time Setting error accuracy Voltage error Note:1) Temperature ...

Page 2

... Screw terminal PM4HW-H-AC240VSW 8 pins PM4HW-H-DC125VW Screw terminal PM4HW-H-DC125VSW 8 pins PM4HW-H-24VW 24V AC/DC Screw terminal PM4HW-H-24VSW 8 pins PM4HW-H-DC12VW 12V DC Screw terminal PM4HW-H-DC12VSW 8 pins PM4HW-H-AC240V Screw terminal PM4HW-H-AC240VS 8 pins PM4HW-H-DC125V Screw terminal PM4HW-H-DC125VS 8 pins PM4HW-H-24V 24V AC/DC Screw terminal PM4HW-H-24VS 8 pins PM4HW-H-DC12V ...

Page 3

PM4H SERIES MODES AND TIME SETTING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. Turn the operation mode selector with screw driver. Operation mode is shown up through the window ...

Page 4

PRECAUTIONS IN USING THE PM4H SERIES 1. Input connections (PM4H-A type sure not to use terminal as the common terminal of the input signal as shown in Fig. A. Otherwise, the internal circuit of the timer may be ...

Page 5

PRECAUTIONS IN USING THE PM4H SERIES 5. Superimposed surge of power supply (PM4H series common) For the superimposed surge of power supply, the standard waveform is taken as the standard value for surge-proof voltage. If external surge occurs exceeding the ...