TLF14CB1821R5 Taiyo Yuden, TLF14CB1821R5 Datasheet - Page 6
TLF14CB1821R5
Manufacturer Part Number
TLF14CB1821R5
Description
CHOKE COMMON MODE 1800UH
Manufacturer
Taiyo Yuden
Series
TLF14CBr
Datasheet
1.TLF9UA102W0R8.pdf
(10 pages)
Specifications of TLF14CB1821R5
Inductance
1.8mH
Current
1.5A
Filter Type
Common Mode - 2 Line Array
Package / Case
0.867" L x 0.669" W x 0.906" H (22.00mm x 17.00mm x 23.00mm)
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Impedance
-
Dc Resistance (dcr)
-
1.Operating Temperature
Range
2.Storage temperature range
3.Rated current
4.Inductance
5.DC resistance
6.Terminal strength
tensile force
7.Temperature rise
8.Insulation resistance
between wires
9.Insulation resistance
between wire and core
△
!
RELIABILITY DATA
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
ー25∼+105℃
ー40∼+85℃
Within the specifed range
Within the specifed tolerance
Within the specifed tolerance
No abnormality
Refer to individual specification
100MΩmin.
BUーRA Type
CMーRA/
CMーRB Type
Specified Value
100MΩmin.
TLF9U:ー25∼+115℃
TLF14CB:ー20∼+105℃
45℃ max.
TLF14CB
TLF9U
ー25∼+105℃
TLF25RA
△
!
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
Including temperature rise due to selfーgenerated heat.
CM:
The maximum DC value having temperature increase
within specified temperature, as detailed in individual
specification.
TLF9UA, 14CB, 25RA:
The maximum AC value having temperature increase
within 45℃ by the application of AC current.
TLF9UB:
The maximum DC value having temperature increase
within 45℃ by the application of DC current.
CM:
Measuring equipmet:4262A (HP) or its equivalent
Measuring frequency:1kHz
TLF9U, 25RA:
Measuring equipment:Impedance analyzer (HP4192A)
Measuring frequency:1kHz
Measuring voltage:0.35Vosc
TLF14CB:
Measuring equipment:LCR meter 4284A or its equivalent
Measuring frequency:1kHz
Measuring voltage:1.0V
CM, TLF:
Measuring equipment:DC ohmmeter
CM:
Fix the component in the direction to draw terminal
and gradually apply tensile force as detailed in indiviual
specifications.
TLF9U:
Apply the stated tensile force gradually in the direction
to draw terminal.
TLF14CB:
Apply the stated tensile force gradually in the direction
to draw terminal.
TLF25RA:
Apply the tensile force of 10N in the direction to draw
terminal for 5 seconds.
TLF:
Resistance substitution method
Applied current:Rated current
Duration:1 hr
CM・TLF:
Applied voltage:Rated voltage (CMーRA/BUーRA、CMーRB)
Duration:60sec.
TLF:
Applied voltage:500VDC (TLF9UA、14CB)
Duration:60 sec.
Nominal wire diameter tensile φd
Nominal wire diameter tensile φd
〔mm〕
〔mm〕
:500VDC (TLF9UA、14CB、25RA)
:250VDC (TLF 9UB)
:250VDC (TLF 9UB)
φ0.6
φ0.8
Test method and remarks
or its equivalent
〔N〕
〔N〕
force
force
10
5
1/4
duration
duration
〔S〕
30±5
〔S〕
30±5
401