HF115AC-0.0055-AC-105 Bergquist, HF115AC-0.0055-AC-105 Datasheet

THERM PAD SIP PKG W/ADH HI-FLOW

HF115AC-0.0055-AC-105

Manufacturer Part Number
HF115AC-0.0055-AC-105
Description
THERM PAD SIP PKG W/ADH HI-FLOW
Manufacturer
Bergquist
Series
Hi-Flow® 115-ACr
Datasheet

Specifications of HF115AC-0.0055-AC-105

Usage
SIP
Shape
Rectangular
Outline
36.83mm x 21.29mm
Thickness
0.0055" (0.140mm)
Adhesive
Adhesive - One Side
Backing, Carrier
Fiberglass
Color
Gray
Thermal Resistivity
0.35°C/W
Thermal Conductivity
0.8 W/m-K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
BER170
HF115AC-105
HF115TAAC-105
The Bergquist Company -
North American Headquarters
18930 West 78th Street
Chanhassen, MN 55317
Phone: 800-347-4572
Fax: 952-835-0430
Features and Benefits
• Thermal impedance:
• Can be applied directly to a cold heat sink
• One side adhesive-coated to aid
• Fiberglass reinforced
Bergquist Hi-Flow 115-AC is a thermally
conductive fiber reinforced phase change
material.The product consists of a thermally
conductive 65°C phase change compound
coated on a fiberglass web, and an adhesive
coating on one side for attachment to a cold
heat sink.There is no need to preheat the
heat sink to apply the Hi-Flow 115-AC.
Hi-Flow 115-AC is designed as a thermal
interface material between a computer
processor and a heat sink.The pressure
sensitive adhesive makes it simple to apply in
high volume to heat sinks and the 65°C phase
change temperature eliminates shipping and
handling problems.
Hi-Flow 115-AC requires no protective liner
for shipping or handling.The Hi-Flow coating
has excellent handling characteristics at room
temperature, and can withstand the handling
and shipping process without protection.
Hi-Flow 115-AC handles like a Sil Pad at
room temperature and flows like high-quality
grease at elevated temperatures.
0.37°C-in
in positioning
2
/W (@25 psi)
The Bergquist Company - Europe
Bramenberg 9a, 3755 BT Eemnes
Netherlands
Phone: 31-35-5380684
Fax: 31-35-5380295
www.bergquistcompany.com
The Bergquist Company - China
Rm. 7C, Aihe Mansion
No. 629 Ling Ling Road
Shanghai, China 200030
Ph: 86-21-6464-2206
Fax: 86-21-6464-2209
Typical Applications Include:
• Computer and peripherals
• As a thermal interface where bare die is exposed and needs to be heat sinked
Configurations Available:
• Sheet form, die-cut parts, and roll form
• With pressure sensitive adhesive
Building a Part Number
Note: To build a part number, visit our website at www.bergquistcompany.com.
Hi- Flow
PROPERTY
Color
Reinforcement Carrier
Thickness (inch) / (mm)
Elongation (%45° to Warp and Fill)
Tensile Strength (psi) / (MPa)
Continuous Use Temp (°F) / (°C)
Phase Change Temp (°F) / (°C)
ELECTRICAL
Dielectric Breakdown Voltage (Vac)
Dielectric Constant (1000 Hz)
Volume Resistivity (Ohm-meter)
Flame Rating
THERMAL
Thermal Conductivity (W/m-K) (1)
THERMAL PERFORMANCE vs PRESSURE
1) This is the measured thermal conductivity of the Hi-Flow coating. It represents one conducting layer in a three-layer laminate.The
Hi-Flow coatings are phase change compounds.These layers will respond to heat and pressure induced stresses.The overall conductivity
of the material in post-phase change, thin film products is highly dependent upon the heat and pressure applied.This characteristic is
not accounted for in ASTM D5470. Please contact Bergquist Product Management if additional specifications are required.
2) The ASTM D5470 (Bergquist modified) test fixture was used and the test sample was conditioned at 70°C prior to test.The
recorded value includes interfacial thermal resistance.These values are provided for reference only. Actual application performance is
directly related to the surface roughness, flatness and pressure applied.
HF115AC
®
Fiberglass-Reinforced, Phase Change Thermal Interface Material
: U.S. Patents 6,197,859 and 5,950,066.
TO-220 Thermal Performance (°C/W)
Thermal Impedance (°C-in
0.0055
TYPICAL PROPERTIES OF HI-FLOW 115-AC
AC
All statements, technical information and recommendations herein are based on tests we believe to be reliable, and
THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MARKETABILITY AND FITNESS FOR PURPOSE. Sellers’ and manufacturers’ only obligation shall be to
replace such quantity of the product proved to be defective. Before using, user shall determine the suitability of the product
for its intended use, and the user assumes all risks and liability whatsoever in connection therewith. NEITHER SELLER NOR
MANUFACTURER SHALL BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, DIRECT,
INCIDENTAL, OR CONSEQUENTIAL, INCLUDING LOSS OF PROFITS OR REVENUE ARISING OUT OF THE USE OR
THE INABILITY TO USE A PRODUCT. No statement, purchase order or recommendations by seller or purchaser not
contained herein shall have any force or effect unless in an agreement signed by the officers of the seller and manufacturer.
12/250
Pressure (psi)
2
/W) (2)
IMPERIAL VALUE
NA
Fiberglass
Hi-Flow
0.0055
Gray
900
302
149
300
10
V-O
3.5
0.8
40
10
1.28
0.44
10
Standard Options
NA = Selected standard option. If not selecting a standard
option, insert company name, drawing number, and
revision level.
_ _ _ = Standard configuration dash number,
1212 = 12" x 12" sheets, 12/250 = 12" x 250' rolls, or
00 = custom configuration
AC = Adhesive, one side
00 = No adhesive
Standard thicknesses available: 0.0055"
HF115AC = Hi-Flow 115-AC Phase Change Material
METRIC VALUE
1.16
0.37
25
Fiberglass
0.139
Gray
V-O
150
300
10
3.5
0.8
40
65
6
10
®
1.04
0.35
50
115-AC
TEST METHOD
PDS_10084_HF_115AC_0305
ASTM D882A
ASTM D882A
0.94
0.27
100
ASTM D3418
ASTM D5470
ASTM D374
ASTM D149
ASTM D150
ASTM D257
U.L. 94
Visual
0.85
0.15
200