EYG-S131810 Panasonic - ECG, EYG-S131810 Datasheet - Page 5

PYROLYTIC GRAPHITE SHT 125X180MM

EYG-S131810

Manufacturer Part Number
EYG-S131810
Description
PYROLYTIC GRAPHITE SHT 125X180MM
Manufacturer
Panasonic - ECG
Series
PGSr
Datasheets

Specifications of EYG-S131810

Usage
Sheet
Shape
Rectangular
Outline
180.00mm x 125.00mm
Thickness
0.004" (0.102mm)
Color
Gray
Thermal Conductivity
600 W/m-K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Adhesive
-
Backing, Carrier
-
Thermal Resistivity
-
Other names
EYGS131810
P11438
“PGS” (Pyrolytic Graphite Sheet) Heat sink sheet
1.
2. Application notes
<Package markings>
Package markings include the product number, quantity, and country of origin.
In principle, the country of origin should be indicated in English.
• When using our products, no matter what sort of equipment they might be used for, be sure to make a written
• Do not use the products beyond the specifi cations described in this catalog.
• This catalog explains the quality and performance of the products as individual components. Be fore use, check
• Install the following systems for a failsafe design to ensure safety if these products are to be used in equip ment
✽ Systems equipped with a protection circuit and a protection device
✽ Systems equipped with a redundant circuit or other system to prevent an unsafe status in the event of a single fault
1.1 The PGS shall be used within the specifi ed operating temperature range.
1.2 The PGS is soft, do not rub or touch it with rough materials to avoid scratching it.
1.3 Lines or folds in the PGS may affect thermal conductivity.
1.4 The PGS shall not be used with acid.
1.5 The PGS shall not be exposed to salt water or direct sunlight during use. The PGS shall not be used in corrosive
1.6 Our PGS has been developed for general industry applications. Prior to using the PGS for special applications
1.7 Never touch a PGS during use because it may be extremely hot.
2.1 Use protective materials when handling and/or applying the PGS, do not use items with sharp edges as they
2.2 The PGS does not work properly if overheated.
2.3 Thermal conductivity is dependant on the way it is used.
2.4 The PGS has conductivity.
2.5 Long term storage
agreement on the specifi cations with us in advance. The design and specifi cations in this catalog are subject
to change without prior notice.
and evaluate their operations when installed in your products.
where a defect in these products may cause the loss of human life or other signifi cant damage, such as damage to
vehicles (au to mo bile, train, vessel), traffi c lights, medical equipment, aerospace equipment, elec tric heating
ap pli anc es, com bus tion/gas equipment, rotating equipment, and disaster/crime prevention equip ment.
PGS (Pyrolytic Graphite Sheet) Heat sink sheet (hereafter referred to as PGS) may result in accidents or trouble
when subjected to severe conditions of electrical, environmental and /or mechanical stress beyond the specifi ed
“Rating” and specifi ed “Conditions” found in the Specifi cations. Please follow the recommendations in “Safety
Precautions” and “Application Notes”. Contact our engineering staff or the factory with any questions.
Safety Precautions
The PGS shall not be used in contact with a soldering iron at 400 °C or more
gases (hydrogen sulfi de, sulfurous acid, chlorine, ammonia etc.).
such as medical, work please contact our engineering staff or the factory.
might tear or puncture the PGS.
Test the adaptability of PGS to your application before use.
If required, the PGS should be provided insulation.
· The PGS shall not be stored under severe conditions of salt water, direct sunlight or corrosive gases (hydrogen
· The PGS shall not be stored near acid.
Safety Precautions
sulfi de, sulfurous acid, chlorine, ammonia etc.).
Handling Precautions
– 380 –
“PGS” Graphite Sheets
00
Sep. 2010

Related parts for EYG-S131810