DA-075-12-02-00-00 Laird Technologies, DA-075-12-02-00-00 Datasheet - Page 2

DIRECT AIR MODULES 7.2A 71W

DA-075-12-02-00-00

Manufacturer Part Number
DA-075-12-02-00-00
Description
DIRECT AIR MODULES 7.2A 71W
Manufacturer
Laird Technologies
Series
DAr
Type
Direct to Air Assemblyr
Datasheet

Specifications of DA-075-12-02-00-00

Voltage
12V
Operating Temperature
-10°C ~ 49°C
Power - Input
86W
Heat Transfer Type
Direct to Air
Power - Cooling
71W
Fan Location
Warm Side
Weight
3.75 lbs (1.7kg)
Dimensions - Overall
230mm L x 122mm W x 67.9mm H
Cooling Power
71 W
Max Heat Load
+ 49 C
Maximum Current
7.2 A
Maximum Voltage
12 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Q5134198
A
B
D
E
F
C
1
1
2
2
q
230
170
120
216
92
3
3
4
2x
O 5.2
WARM SIDE
COLD SIDE
5
Comments / deviations:
Heat sinks and, if applicable, D-plates and shrouds in anodised aluminium.
Designed by:
Pavel Cech
Approved by:
Hans Lindberg
Jumpers
tfn: +46 31 420530, fax: +46 31 247909
Box 27, S-40120 Göteborg, Sweden
e-mail: info@supercool.se
Web: www.supercool.se
Supercool AB
6
6
This drawing is the property of Supercool AB. Protected in accordance with prevailing law.
3.2
122
60
Electrical connections:
"+": + TEM
"-": - TEM
"F+": + Fan(s)
"F-": - Fan(s)
To use single supply:
Lift the jumpers and rotate 90° to short-cut the
pin pairs.
Connect the unit to "+" & "-".
Warning: Single supply not applicable in heating
mode or with PWM-regulation.
Release date:
20041109
Title:
Part nr:
DA-075-12-02-00-00
TE ASSEMBLY 12VDC DIRECT - AIR
r 0.1/100
7
7
Customer:
Supercool AB
Rev. nr.
0
General tolerances:
SS-ISO 2768-1 c
Status:
0
8
8
Project:
HDPC
Scale: Size, sheet
1:2
A3, 2(3)
A
B
C
F
D
E