7-103639-1 TE Connectivity, 7-103639-1 Datasheet

Conn Shrouded Header HDR 22 POS 2.54mm Solder ST Thru-Hole Tube

7-103639-1

Manufacturer Part Number
7-103639-1
Description
Conn Shrouded Header HDR 22 POS 2.54mm Solder ST Thru-Hole Tube
Manufacturer
TE Connectivity
Type
Shrouded Headerr
Series
MTE Seriesr
Datasheet

Specifications of 7-103639-1

Pitch
2.54 mm
Number Of Rows
1
Number Of Contacts
22
Gender
HDR
Contact Plating
Tin Over Nickel
Termination Method
Solder
Product Type
Plugs - PCB
Contact Gender
Pin (Male)
Number Of Positions / Contacts
22
Row Spacing
2.54 mm
Mounting Style
Through Hole
Mounting Angle
Vertical
Termination Style
Crimp
Housing Material
Thermoplastic, Glass Filled
Contact Material
Brass
Operating Temperature Range
- 65 C to + 105 C
Connector Type
Header
Post Size (mm [in])
0.64 [.025]
Pcb Mounting Orientation
Vertical
Termination Method To Wire/cable
Crimp, Insulation Displacement Crimp (IDC)
Pcb Mount Style
Through Hole
Pcb Mount Retention
Without
Connector Series
MTE
Solder Tail Contact Plating
Matte Tin
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
2.54 [0.100]
Number Of Positions
22
Contact Type
Pin
Pcb Orientation Feature
No
Contact Plating, Mating Area, Material
Matte Tin
Contact Base Material
Brass
Contact Shape
Square
Connector Style
Plug
Mating Alignment
With
Mating Alignment Type
Latched
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Operating Temperature (°c)
-65 – +105
Applies To
Printed Circuit Board
Packaging Method
Tube
Lead Free Status / Rohs Status
 Details
5
88
Wire Sizes
Contact Platings
Mating Post Lengths
Application Tooling
Catalog 1307819
Revised 8-08
www.tycoelectronics.com
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
AMPMODU Interconnection System
Wire-to-Board, .100 [2.54] Centerline Products
Manual Hand Tools (Wire Crimp)
AMP-O-MATIC Stripper/Crimper
AMPOMATOR CLS Machines
Manual Hand Tools (IDC)
Machines with Applicator
Machines with Applicator
.210-.283 [5.33-7.19]
.205-.283 [5.21-7.19]
.185-.283 [4.70-7.19]
.256-.323 [6.50-8.20]
.251-.323 [6.38-8.20]
.231-.323 [5.87-8.20]
.222-.273 [5.64-6.93]
.200-.273 [5.08-6.93]
.200-.250 [5.08-6.35]
.169-.259 [4.29-6.58]
.273-.350 [6.93-8.89]
.200-.277 [5.08-7.04]
22-30
AWG
.000015 [0.00038]
.000030 [0.00076]
.000050 [0.00127]
IDC Electric Power Unit
Pneumatic Hand Tools
Discrete Wire Machine
Pneumatic Arbor Tool
20
32
Application Tooling
Model 2.5 Machine
Model 3A Machine
Post Lengths
Manual Arbor Tool
CHAMPOMATOR
CHAMPOMATOR
AMP-O-LECTRIC
Tube-Fed Ribbon
Cable Machine
Wire Size
Platings
Description
Gold
Gold
Gold
Tin
0.3-0.05
0.5-0.6
[mm
0.03
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
2
]
Mod. IV,
IV.v, V
Locking Clip, Mod. IV , IV .v, V , MTE, MT, Short Point
Locking Clip, Mod. IV , IV .v, V , MTE, MT, Short Point
Locking Clip, Mod. IV , IV .v, V , MTE, MT, Short Point
MT Assembly with Standard Pressure Contacts
Locking Clip, Mod. IV , IV .v, V , MT, Short Point
MT Assembly with High Pressure Contacts
Mod. IV .v (.600 [15.24] Profile Height)
Mod. IV .v (.645 [16.38] Profile Height)
Mod. IV , IV .v, V , MTE, MT, Short Point
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
Mod. IV (.600 [15.24] Profile Height)
Mod. IV (.645 [16.38] Profile Height)
Locking Clip (Connector Assembly)
Mod. V (.600 [15.24] Profile Height)
Mod. V (.645 [16.38] Profile Height)
Short Point Connector Assembly
Locking Clip, Mod. IV , IV .v, V , MT
Locking Clip (Single Contact)
MT
Mod. IV , IV .v, V , Short Point
Product Family
Product Family
Product Family
MTE Assembly
Locking
Clip
Product Family
MTE
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208
Short
Point
Level V

Related parts for 7-103639-1

7-103639-1 Summary of contents

Page 1

... USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 2

... Catalog Page(s) 220 230, 231, 244-250 256-258 224 211-213 230, 231, 236, 237 242 207-209 248, 249 ...

Page 3

... Contact Termination Resistance — 15 milliohms (max.) Dielectric Withstanding Voltage — At Sea Level–600 VAC, rms At 70,000 Ft. [21 336 m]–225 VAC, rms Insulation Resistance — 5,000 megohms (min.) Environmental Characteristics Operating Temperature — -65°C to +105°C Vibration — ...

Page 4

... Headers, Polarized/Latching, Right Angle Post, with or without Holddown (See pages 246 & 247) AMPMODU Breakaway Headers, Single-Row Coupling Shroud (See page 240) Dimensions are shown for reference purposes only. Specifications subject to change ...

Page 5

... AMPMODU Interconnection System MTE Interconnection System Wire-to-Wire Pin Assemblies, Shrouded Polarized/Latching (See pages 236 & 237) Receptacle Assemblies, Polarized/Latching (See pages 230 & 231) Receptacle Contact, Insulation Displacement (Used in all Receptacle Assemblies) Crimp Snap-In Receptacle Contact (Used with Unloaded Housings— ...

Page 6

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Mateable AMPMODU Products Breakaway Headers — ...

Page 7

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. ...

Page 8

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data ...

Page 9

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. ...

Page 10

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Coupling Shrouds used with — ...

Page 11

... Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. Note: All part numbers are RoHS compliant. ...

Page 12

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insulation wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max ...

Page 13

... Material and Finish Housing — Thermoplastic, black, 94V-0 rated Contacts — Phosphor Bronze, duplex plated .000030 [0.00076] gold on contact area, .000050 [0.00127] min. tin on crimp area, with entire contact underplated .000050 [0.00127] nickel. Related Product Data Coupling Shrouds used with — ...

Page 14

... Plating C — .000100 [0.00254] tin over .000050 [0.00127] nickel on entire contact 5 Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU Products — Receptacle Assemblies (Polarized/Latching) — ...

Page 15

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove pin contacts. Note: All part numbers are RoHS compliant. Catalog 1307819 ...

Page 16

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU MTE Products (with Pin Assembly Installed in Panel Mount Pin Shroud) — ...

Page 17

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove pin contacts. Note: All part numbers are RoHS compliant. Catalog 1307819 ...

Page 18

... Single-Row Material Black thermoplastic, 94V-0 rated Technical Documents — pages 277, 278 Product Specification 108-25034 Application Specification 114-25026 5 240 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Coupling Shrouds for MTE Receptacle Assemblies with Guide Ribs A ...

Page 19

... Coupling Shrouds for MTE Receptacle Assemblies with Guide Ribs Double-Row Material Black thermoplastic, 94V-0 rated Technical Documents — Position No. 1 Identification pages 277, 278 Product Specification 108-25034 Application Specification 114-25026 Receptacle Assemblies with Guide Ribs (Refer to pages 232, 233 & 235) 1 Mating AMPMODU Double-Row Shrouded Headers must have ...

Page 20

... USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 .250 [6.35] Panel Mount Pin Shroud ...

Page 21

... AMPMODU Interconnection System Panel Mount Pin Shrouds for MTE Pin Assemblies with Guide Ribs, Single-Row Material Black thermoplastic, 94V-0 rated Technical Documents — pages 277, 278 Product Specification 108-25034 Application Specification 114-25026 Receptacle Assemblies with Guide Ribs, Installed in Single-Row Coupling Shroud (Refer to pages 232, 233, 235 & ...

Page 22

... Material and Finish Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [0.00076] gold on contact area, .000100 [0.00254] min. tin on solder area, with entire post underplated .000050 [0.00127] nickel Plating B — Duplex plated .000015 [0 ...

Page 23

... South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 5 245 ...

Page 24

... X .060 [1.52] .340±.003 .100* Typ. [8.64±0.08] [2.54] Recommended PC Board Hole Layout (PC board thickness (for Holddown Feature) is .062±.008 [1.57±0.20]) *±.003 [±0.08]; tolerance not to accumulate within one connector pattern. Without Holddown A B .060 [1.52] C .100 Typ. ...

Page 25

... Notes: 1. Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and ...

Page 26

... Post (With Swaged Tails and PC Board Orientation) Material and Finish Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated .000100 [0.00254] tin over .000050 [0.00127] nickel on entire post Related Product Data Mateable AMPMODU MTE Products — Receptacle Assemblies (Polarized/Latching) — ...

Page 27

... Mateable AMPMODU MTE Products — Receptacle Assemblies with Guide Ribs (installed in Single-Row Coupling Shroud) — pages 232, 233, 235, 240 Receptacle Assemblies (Polarized Latching) — pages 230, 231 Technical Documents — pages 277, 278 Product Specification 108-25034 Application Specification 114-25026 No. of Pos ...

Page 28

... Mateable AMPMODU MTE Products — Receptacle Assemblies (Polarized/ Latching) — pages 230, 231 Receptacle Assemblies with Guide Ribs (installed in Single-Row Coupling Shroud) — pages 232, 233, 235, 240 Technical Documents 5 — pages 277, 278 Product Specification 108-25034 Application Specification 114-25026 Dimensions No. of Pos ...

Page 29

... Material and Finish Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [.00076] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. K Plating B — Duplex plated .000015 [ ...

Page 30

... Material and Finish Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [.00076] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating B — Duplex plated .000015 [ ...

Page 31

... Plating C *For use with Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 32

... AMP-O-LECTRIC Model “K” machines. Call Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. Note: These wire crimp contacts can be intermixed with insulation displacement crimp contacts. ...

Related keywords