W2G110-AK43-31 EBM-Papst Industries Inc, W2G110-AK43-31 Datasheet

FAN TUBEAXIAL 119X38MM 24VDC

W2G110-AK43-31

Manufacturer Part Number
W2G110-AK43-31
Description
FAN TUBEAXIAL 119X38MM 24VDC
Manufacturer
EBM-Papst Industries Inc
Series
W1G110r

Specifications of W2G110-AK43-31

Current Type
DC
Supply Voltage
24 V
Bearing Type
Ball
Termination Style
61 dB(A)
Fan Type
Tubeaxial
Size / Dimension
Square - 119mm L x 119mm H x 38mm W
Voltage - Rated
24VDC
Power (watts)
15.0W
Features
Locked Rotor Sensor
Rpm
4400 RPM
Noise
61 dB(A)
Air Flow
140.0 CFM (3.96m³/min)
Termination
2 Terminals
Weight
1.1 lbs (498.9g)
Voltage Range
16 ~ 28VDC
Airflow
140 CFM
Power Rating
1.5 W
External Height
119mm
External Width
119mm
External Depth
38mm
Flow Rate
156CFM
Noise Rating
54dBA
Power Connection Type
Lead Wires
Product
Fans
Brand/series
W2G110
Dimensions
150 x 55 mm
Power, Rating
11 W
Size
5.91 x 2.17 (150 x 55) In. (mm)
Voltage, Rating
N24 VDC
Flow Rate - Imperial
156CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-2323
W2G110-AK43-31
W2G110AK4331
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone: +49(0)7938/81-0
Fax: +49(0)7938/81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
1.1 Levels of hazard warnings
1.2 Staff qualification
1.3 Basic safety rules
1.4 Electrical voltage
1.5 Safety and protective functions
1.6 Electromagnetic radiation
1.7 Mechanical movement
1.8 Emission
1.9 Hot surface
1.10 Transport
1.11 Storage
1.12 Disposal
2. PROPER USE
3. TECHNICAL DATA
3.1 Graphic rendition of products
3.2 Nominal data
3.3 Technical description
3.4 Mounting data
3.5 Storage conditions
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.3 Connection via plug
4.4 Connection diagram
4.5 Checking the connections
4.6 Switch on device
4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
5.1 Cleaning
5.2 Safety test
Item no.: 50872-5-9970 · Revision status: KM71618 · Print-out on 21/10/2010 · Created by A. Kehm (VM---) · Page 1 of 8
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2G110-AK43-31
Operating instructions
1
1
1
1
1
2
2
2
2
2
2
2
2
3
4
4
5
5
5
5
5
5
5
5
6
7
7
7
7
8
8
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
1.2 Staff qualification
Only specialised electrical personnel may install the device, perform the
test run and work on the electrical system.
Only trained and authorised specialist personnel are permitted to
transport, unpack, assemble, operate or maintain the device, or to use it
in any other manner.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:
1.4 Electrical voltage
Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
Check the electrical equipment of the device at regular intervals.
Remove loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains

Related parts for W2G110-AK43-31

W2G110-AK43-31 Summary of contents

Page 1

... W2G110-AK43-31 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone: +49(0)7938/81-0 Fax: +49(0)7938/81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1.2 Staff qualification 1.3 Basic safety rules 1.4 Electrical voltage 1.5 Safety and protective functions 1.6 Electromagnetic radiation 1 ...

Page 2

... W2G110-AK43-31 supply voltage and secure the latter from being switched on again. Wait until the device stops. 1.5 Safety and protective functions DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example by reaching into the running device with your hands. ...

Page 3

... W2G110-AK43-31 2. PROPER USE The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. ...

Page 4

... W2G110-AK43-31 3. TECHNICAL DATA 3.1 Graphic rendition of products All measures have the unit mm. 1 Direction of air flow "A" flat plugs 2.8x0.5 (AMP no. 170058-2) Item no.: 50872-5-9970 · Revision status: KM71618 · Print-out on 21/10/2010 · Created by A. Kehm (VM---) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com ...

Page 5

... W2G110-AK43-31 3.2 Nominal data Motor M2G045-BA Nominal voltage [VDC] 24 Nominal voltage range [VDC] Type of data definition rfa -1 Speed [min ] 4400 Power input [W] 15 Max. back pressure [Pa] 100 Min. ambient - 25 temperature [°C] Max. ambient +72 temperature [° max. load · max. efficiency · rfa = running at free air cs = customer specs · ...

Page 6

... W2G110-AK43-31 4.4 Connection diagram Item no.: 50872-5-9970 · Revision status: KM71618 · Print-out on 21/10/2010 · Created by A. Kehm (VM---) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Operating instructions ...

Page 7

... W2G110-AK43-31 4.5 Checking the connections Make sure that the power is off (all phases). Secure it from being switched on again. Check that the mating connector is correctly locked into the panel connector. Check that the mating connector is correctly crimped to the connection line. 4.6 Switch on device ...

Page 8

... W2G110-AK43-31 5.1 Cleaning NOTE Damage to the device during cleaning. Malfunction possible Do not clean the device using a water jet or high-pressure washer. Do not use any cleaners containing acids, bases or solvents. 5.2 Safety test What has to be How to test? tested? Protective casing Visual inspection ...

Related keywords