W2E200-HH86-01 EBM-Papst Industries Inc, W2E200-HH86-01 Datasheet - Page 6

FAN EXHAUST 225 X 80MM 115VAC

W2E200-HH86-01

Manufacturer Part Number
W2E200-HH86-01
Description
FAN EXHAUST 225 X 80MM 115VAC
Manufacturer
EBM-Papst Industries Inc
Series
W2E200Hr
Type
Squarer

Specifications of W2E200-HH86-01

Bearing Type
Ball
Voltage Rating
115VAC
Power (watts)
80W
Size / Dimension
Square - 225mm L x 225mm H x 80mm W
Termination
4 Position Terminal Block
Fan Type
Tubeaxial
Termination Style
61 dB(A)
Air Flow
607.0 CFM (17.19m³/min)
Weight
4.7 lbs (2.1kg)
Rpm
2800 RPM
Noise
61 dB(A)
External Height
225mm
External Width
225mm
External Depth
80mm
Current Type
AC
Supply Voltage
115VAC
Flow Rate
607CFM
Noise Rating
61dBA
Power Connection Type
Terminal
Airflow
606 CFM
Frame Dimensions (mm)
225 mm x 80 mm
Power Rating
80 W
Brand/series
W2E200
Dimensions
225 x 80 mm
Direction
Exhaust over Struts
Noise Level
61 dBA
Size
8.86 x 3.15 (225 x 80) In. (mm)
Temperature, Operating, Maximum
+65 °C
Thickness
80 mm
Voltage, Rating
115 VAC
Flow Rate - Imperial
607CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-1114::W2E200HH8601
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.2.1 Prerequisites
4.2.2 Voltage control
Item no.: 10983-5-9970 · Revision status: KM71618 · Print-out on 06/08/2010 · Created by Y. Uhlmann (VM-TDO) · Page 6 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
W2E200-HH86-01
Install the device according to your application.
Check whether the data on the type plate agree with the connection
data and the data of the operating capacitor.
Before connecting the device, ensure that the supply voltage matches
the operating voltage of the device.
Only use cables designed for current according to the type plate.
CAUTION
Cutting and crushing hazard when removing the fan
from the packaging
DANGER
Electric voltage on the device
Electric shock
CAUTION
Electrical voltage
The fan is a built-in component and features no electrically
isolating switch.
NOTE
Water penetration into leads or wires
Water enters at the cable end on the customers side and can
damage the device.
Connect the device only to circuits that can be switched off
using an all-pole disconnecting switch.
With open loop speed control using transformers or electronic
voltage regulators (e.g. phase angle control), excessive current
may occur.
In addition, noises can occur with phase angle control
depending on the mounting situation.
Carefully lift the fan out of its packaging, only touching the
housing. Make sure to avoid any shock.
Wear safety shoes and cut-resistant safety gloves.
Always install a protective earth.
Check the protective earth.
Only connect the fan to circuits that can be switched off with
an all-pole separating switch.
When working on the fan, you must switch off the
installation/machine in which the fan is installed and secure it
from being switched on again.
Make sure that the cable end is connected in a dry
environment.
Operating instructions
4.2.3 Frequency inverter
4.3 Connection via terminal strip
4.3.1 Connecting cables with terminals
Guide the wires into the terminals, see
chapter 4.4 Connection diagram.
Fit sinusoidal filters that work on all poles (live-live and live-
earth) between the frequency inverter and the motor for
operation with frequency inverters.
Depending on how the device is installed, noises may occur.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.