BTA216-600B,127 NXP Semiconductors, BTA216-600B,127 Datasheet - Page 6

TRIAC 600V 16A SOT78

BTA216-600B,127

Manufacturer Part Number
BTA216-600B,127
Description
TRIAC 600V 16A SOT78
Manufacturer
NXP Semiconductors
Datasheet

Specifications of BTA216-600B,127

Package / Case
TO-220AB-3
Triac Type
Standard
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
60mA
Voltage - Off State
600V
Current - Gate Trigger (igt) (max)
50mA
Current - Non Rep. Surge 50, 60hz (itsm)
140A, 150A
Current - On State (it (rms)) (max)
16A
Voltage - Gate Trigger (vgt) (max)
1.5V
Current - On State (it (rms) (max)
16A
Rated Repetitive Off-state Voltage Vdrm
600 V
Breakover Current Ibo Max
150 A
On-state Rms Current (it Rms)
16 A
Off-state Leakage Current @ Vdrm Idrm
0.1 mA
Gate Trigger Voltage (vgt)
0.4 V
Gate Trigger Current (igt)
18 mA
Holding Current (ih Max)
60 mA
Forward Voltage Drop
1.2 V
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Repetitive Peak Forward Blocking Voltage
600 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
934020220127
BTA216-600B
BTA216-600B

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTA216-600B,127
Manufacturer:
NXP Semiconductors
Quantity:
3 200
Philips Semiconductors
DEFINITIONS
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices or systems where malfunction of these
products can be reasonably expected to result in personal injury. Philips customers using or selling these products
for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting
from such improper use or sale.
October 1997
Three quadrant triacs
high commutation
Data sheet status
Objective specification
Preliminary specification This data sheet contains preliminary data; supplementary data may be published later.
Product specification
Limiting values
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one
or more of the limiting values may cause permanent damage to the device. These are stress ratings only and
operation of the device at these or at any other conditions above those given in the Characteristics sections of
this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be
accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any
consequence of its use. Publication thereof does not convey nor imply any license under patent or other
industrial or intellectual property rights.
Philips Electronics N.V. 1997
This data sheet contains target or goal specifications for product development.
This data sheet contains final product specifications.
6
BTA216 series B
Product specification
Rev 1.200

Related parts for BTA216-600B,127