ACST8-8CT STMicroelectronics, ACST8-8CT Datasheet - Page 7

IC AC POWER SWITCH TO-220AB

ACST8-8CT

Manufacturer Part Number
ACST8-8CT
Description
IC AC POWER SWITCH TO-220AB
Manufacturer
STMicroelectronics
Series
ASD™r
Datasheet

Specifications of ACST8-8CT

Triac Type
Standard
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
40mA
Voltage - Off State
800V
Current - Gate Trigger (igt) (max)
30mA
Current - Non Rep. Surge 50, 60hz (itsm)
80A, 85A
Current - On State (it (rms)) (max)
8A
Voltage - Gate Trigger (vgt) (max)
1.5V
Package / Case
TO-220-3
Current - On State (it (rms) (max)
8A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-3380

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACST8-8CT
Manufacturer:
ST
0
Part Number:
ACST8-8CT������
Manufacturer:
ST
0
ACST8
2.2
AC line transient voltage ruggedness
In comparison with standard Triacs, which are not robust against surge voltage, the ACST8
is self-protected against over-voltage, specified by the new parameter V
switch can safely withstand AC line transient voltages either by clamping the low energy
spikes, such as inductive spikes at switch off, or by switching to the on state (for less than 10
ms) to dissipate higher energy shocks through the load. This safety feature works even with
high turn-on current ramp up.
The test circuit of
ACST switch according to the IEC 61000-4-5 standard conditions. With the additional effect
of the load which is limiting the current, the ACST switch withstands the voltage spikes up to
2 kV on top of the peak line voltage. The protection is based on an overvoltage crowbar
technology. The ACST8 folds back safely to the on state as shown in
recovers its blocking voltage capability after the surge and the next zero current crossing.
Such a non repetitive test can be done at least 10 times on each AC line voltage polarity.
Figure 17. Overvoltage ruggedness test circuit for resistive and inductive loads for
AC Mains
IEC 61000-4-5 standards
Filtering unit
Figure 17
represents the ACST8 application, and is used to stress the
R = 13 , L = 2 µH, Vsurge = 2 kV
Doc ID 7463 Rev 9
Surge generator
Rg = 82
2kV surge
Rgene
Model of the load
R
L
Application information
Figure
CL
. The ACST8
18. The ACST8
ACST8
Rg
7/13

Related parts for ACST8-8CT