ACS102-6TA-TR STMicroelectronics, ACS102-6TA-TR Datasheet - Page 7

IC AC SWITCH .2A 600V TO-92

ACS102-6TA-TR

Manufacturer Part Number
ACS102-6TA-TR
Description
IC AC SWITCH .2A 600V TO-92
Manufacturer
STMicroelectronics
Series
ACS™r
Datasheet

Specifications of ACS102-6TA-TR

Triac Type
Alternistor - Snubberless
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
20mA
Voltage - Off State
600V
Current - Gate Trigger (igt) (max)
5mA
Current - Non Rep. Surge 50, 60hz (itsm)
7.3A, 7.6A
Current - On State (it (rms)) (max)
200mA
Voltage - Gate Trigger (vgt) (max)
900mV
Package / Case
TO-92-3 (Standard Body), TO-226
Current - On State (it (rms) (max)
200mA
Peak Repetitive Off-state Voltage, Vdrm
600V
Gate Trigger Current Max (qi), Igt
5mA
On State Rms Current It(rms)
200mA
Peak Non Rep Surge Current Itsm 50hz
7.3A
Holding Current Max Ih
20mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5566-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS102-6TA-TR
Manufacturer:
ST
0
ACS102-6T
2.1.2
Figure 14. Effect of the switching off of a high
Figure 16. Overvoltage ruggedness test circuit
Surge generator
"1.2/50 waveform"
100µs/div
2.4 kV surge
Rgene
I
(5 mA/div)
OUT
2
1
I
H
AC line transient voltage ruggedness
The ACS102-6T switch is able to withstand safely the AC line transients either by clamping
the low energy spikes or by breaking over under high energy shocks, even with high turn-on
current rises.
The test circuit shown in
is also used to test the ACS switch according to the IEC 61000-4-5 standard conditions.
Thanks to the load limiting the current, the ACS102-6T switch withstands the voltage spikes
up to 2 kV above the peak line voltage. The protection is based on an overvoltage crowbar
technology. Actually, the ACS102-6T breaks over safely as shown in
ACS102-6T recovers its blocking voltage capability after the surge (switch off back at the
next zero crossing of the current).
Such non-repetitive tests can be done 10 times on each AC line voltage polarity.
inductive load - typical clamping
capability of ACS102-6T
for resistive and inductive loads
with conditions equivalent to
IEC 61000-4-5 standards
2
3
4
Model of the load
150
R
V
(200 V/div)
V
OUT
PEAK
5
5µH
= V
L
CL
Figure 16
ACS102-6Tx
Rg
220
is representative of the final ACS102-6T application, and
Figure 15. Description of the different steps
Figure 17. Typical current and voltage
200ns/div
V
(200 V/div)
V
OUT
PEAK
during switching off of a high
inductive load
waveforms across the ACS102-6T
during IEC 61000-4-5 standard test
AC line switch - basic application
I
I
I
I
OUT
OUT
H
H
5
5
2
2
1
1
Figure
3
3
I
(2 A/div)
4
4
OUT
17. The
V
V
CL
CL
V
V
OUT
OUT
7/11

Related parts for ACS102-6TA-TR