58247-1 TE Connectivity, 58247-1 Datasheet - Page 3

no-image

58247-1

Manufacturer Part Number
58247-1
Description
Connector Accessories MTA Terminating Head
Manufacturer
TE Connectivity
Type
Headr
Datasheets

Specifications of 58247-1

Product Length (mm)
89mm
Product Depth (mm)
25.4mm
Tooling ,tyco Electronics / Amp
ROHS COMPLIANT
Application
Terminating Head
Tool Type
Hand Tool Head
Lead Free Status / RoHS Status
RoHS Not Applicable
For Use With
Pistol Grip Hand Tool
Lead Free Status / RoHS Status
RoHS Not Applicable
Rev D
Note:
Connector
Index Rib
Left Side of Head
3. Insert an unstripped wire into the funnel area
between contact and wire inserter until the wire
bottoms on the tool base.
4. Depress the trigger (or squeeze the cam
handle) of the pistol grip handle assembly and hold
until the inserter bottoms or ratchet releases.
5. Release trigger (or cam handle). The inserter
will retract and the feed slide will automatically
advance the connector to the next contact position.
NOTE
6. Repeat Steps 2 through 5 until all contacts have
been terminated. Inspect each termination
according to Section 5, TERMINATION
INSPECTION.
1
Locating
Pawl
/
6
Counterclockwise to Increase
Wire Insertion Depth
turn equals 0.20 [.008] adjustment.
Tool
Base
The locating pawl will move up and down as the
connector automatically advances through the
head. However, if movement is obstructed, or if
desirable, the locating pawl can be depressed
and the connector moved manually out the
RIGHT side of the head.
Terminating Connector
Figure 4
Figure 5
Wire
Clockwise to Reduce
Wire Insertion Depth
MTA Terminating Head 58247–1
Adjuster
Handle
Assembly
(Ref)
5. TERMINATION INSPECTION
Inspect each termination to ensure the following:
6. MAINTENANCE AND INSPECTION
The head is inspected before shipment. It is
recommended that the head be inspected
immediately upon arrival at your facility to ensure that
the head conforms to the dimensions provided in
Section 7 and that the head has not been damaged
during transit. Each operator should be aware of, and
responsible for, the following:
6.1. Daily Maintenance
6.2. Periodic Maintenance
Regular inspections should be performed by quality
control personnel with a record of these control
inspections remaining with the personnel responsible
for the head. Tyco Electronics recommends one
inspection a month; however, operator training and
skill, amount of use, ambient working conditions, and
your company’s established standards are all factors
in establishing frequency of inspections. These
inspections should be performed in the following
sequence:
NOTE
— conductor is terminated past the lead–in
transition and about halfway in the contact slot
— insulation is 1.52 [.060] (minimum) beyond the
front contact beam (see Figure 3)
— wire is NOT bottomed in contact slot
— contact beams are NOT deformed. If damage is
apparent, replace contacts in accordance with the
instructions packaged with the connector
— insulation of wire is NOT nicked or cut in any
area other than the two wire slots
— wire extends below the strain–relief features of
connector
1. Remove dust, moisture, and other contaminants
with a clean brush, or soft, lint–free cloth. Do NOT
use objects that could damage the head.
2. Make sure all components are in place and
properly secured. If NOT, refer to Section 7 for
information on obtaining evaluation and repair.
3. Actuate handle assembly to ensure
mechanisms inside head move smoothly.
1. Remove any accumulated film with a suitable
cleaning agent that will NOT affect plastic material.
2. Make sure all components are in place and
properly secured. Refer to Section 7.
3. Make a few test terminations and inspect the
terminations in accordance with Section 5,
TERMINATION INSPECTION.
For detailed inspection requirements, refer to
Application Specification 114–1020.
408–6930
3 of 5

Related parts for 58247-1