Agency Approvals
UL:
CSA: Accepted as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Electrical Data
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Approvals and Ratings Table 1
W6 Series
W9 Series
Features
• Designed for the international market. UL Recognized, CSA Accepted,
• Ratings to 50 amps.
• Heavy duty #10-32 stud connections. (W9)
• Quick-connect or screw terminals. (W6)
• Optional 10 amp auxiliary switch.
• Several delay curve options.
• Trip-free operation.
Calibration: Breakers will hold 100% of rated current.
Approvals and Ratings Table 2
UL/CSA
§ Note: 277/480VAC,3Ø-Wye, rating is UL, but not CSA.
§ Note: 277/480VAC,3Ø-Wye, rating is UL, but not CSA.
and VDE approved.
Maximum
Maximum
277/480 §
277/480 §
Voltage
Voltage
Number
Switch
277
277
277
65
65
Recognized as Supplementary Protector under UL 1077 . File
E69543.
License No. 73782.
A
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Breakers may trip between 101% and 124% of rated load
(134% for AC/DC units).
Breakers must trip at 125% of rated load and above (135%
for AC/DC units).
Frequency
Frequency
50/60
50/60
50/60
(Hz)
50/60
50/60
50/60 Hz.
DC
(Hz)
Voltage
DC
UL/CSA (All Circuit Functions)
UL/CSA (All Circuit Functions)
125
3Ø-Wye
3Ø-Wye
Phase
Phase
1
1
-
1
-
Current
(Amps)
10
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Current
(Amps)
0.2 - 50
0.2 - 20
0.2 - 20
Current
Rating
21 - 50
(Amps)
0.2 - 50
0.2 - 50
0.2 - 20
Rating
.093 x .020 x .250
(2.36 x .51 x 6.40)
Terminals
WxTxL
Interrupting
Interrupting
Capacity
(Amps)
Capacity
(Amps)
2,000
5,000
2,500
5,000
2,000
5,000
5,000
Issued 3-03 (PDF Rev. 11-06)
Catalog 1308242
W6 Series
W9 Series
Maximum
Specifications and availability
subject to change.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)
Fungus And Moisture Resistance: Special moisture resistant finish
Marking: W6 units have ON and OFF molded on the rocker of rocker
Mounting: Units are mounted with two #6-32 screws from the front of the
Weight: Approximately 2.5 ounces per pole.
Typical Resistance and Impedance
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
Voltage
415/240
W6/W9
Magnetic Hydraulic
Circuit Breakers
Maximum
Voltage
415/240
250
250
65
250
250
65
(100g @ 6 ms).
Current
(Amps)
total excursion in 2 planes.
actuated units (rocker actuated VDE units have international
“1” and “0”). W9 units have ON and OFF molded into the area
at the base of the toggle. International “1” and “0” symbols are
marked on the toggle for both W6 and W9.
20.0
30.0
40.0
50.0
10.0
0.2
1.0
2.0
5.0
panel. Metric models for use with M3 x 0.5 screws are
available. To maintain published performance specifications,
units should not be mounted more than 90° from their normal
upright position.
Frequency
Frequency
50/60
50/60
50/60
50/60
50/60
50/60
(Hz)
(Hz)
DC
DC
VDE (Circuit Function X)
VDE (Circuit Function X)
series
Phase
Phase
3Ø
Resistance
3Ø
1
1
-
1
1
-
(Ohms)
90
DC
1.2
0.28
0.04
0.013
0.004
0.0027
0.002
0.0015
applied to all ferrous parts.
Plastic parts are made of inherently
fungus resistant material.
Current
(Amps)
Current
(Amps)
Rating
Rating
0.2-50
0.2-30
0.2-30
0.2-50
0.2-30
0.2-30
31-50
31-50
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Impedance
50/60 Hz.
Interrupting
(Ohms)
Interrupting
90
Capacity
1.2
0.28
0.04
0.013
0.005
0.004
0.002
0.0015
Capacity
(Amps)
(Amps)
2,000
5,000
2,000
5,000
2,000
5,000
2,000
5,000
P&B
119