Specifications of PL110800CC

Operating Temperature Range
0 C to + 105 C
Termination Style
Through Hole
Dimensions
26.42 mm L x 21.84 mm W x 23.37 mm H
Product
Telecom Transformers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PL-11, PL-12, PL-13, PL-14, PL-32, PL-33, PL-34
Vishay Dale
ELECTRICAL SPECIFICATIONS
Input Voltage: 115 V, 60 Hz
Output Power Rating:
PL-11 = 0.75 VA
PL-12, PL-32 = 1.50 VA
PL-13, PL-33 = 4.50 VA
PL-14, PL-34 = 10.0 VA
Dielectric Strength: All models are 1500 V, 60 Hz from
primary to secondary winding and all windings to core
Temperature Class: Insulation Class A, + 105 °C
www.vishay.com
1
Secondary: PL-11 thru PL-14, Single Secondary: PL-32 thru PL-34
SCHEMATICS
Basic Style
Options
Low Power Transformers Single Primary, Input 115 V Dual
2
1
Connected
Series
P
3
6
4
5
L
1 -
Output
Volts
, 1
P
L
For technical questions, contact:
1 -
, 2
P
L
1
2
1 -
PL-11, PL-12, PL-13, PL-14
, 3
50 - 60 Hz
Connected
P
Parallel
2
1
115 V
L
1 -
4
3
4
5
6
magnetics@vishay.com
Output
FEATURES
• PC pin mounting
• Provides isolation from power line
• Mounting frames and bobbin standoff are
• Modification to these standard items are available as
• Laminated construction for low-cost industrial applications,
• PL-11, PL-12, PL-13, PL-14: Dual secondaries for series
• PL-32, PL-33, PL-34: Single secondary and lower cost
• Compliant to RoHS directive 2002/95/EC
MECHANICAL SPECIFICATIONS
Terminals Brass, solder coated
Weight: (reference)
PL-11 = 35 g
PL-12, PL-32 = 100 g
PL-13, PL-33 = 160 g
PL-14, PL-34 = 240 g
Volts
available
specially products
including power supplies, controls and instrumentation
connection to obtain twice voltage with center tap or
parallel connection for twice current rating
construction. Recognized under the Component Program
of Underwriters Laboratories, Inc., U.L. Files E71961. For
general purpose transformers (U.L. Standard 506).
5
3
4
6
115 V 50 Hz to 60 Hz
P
L
1
3
3 -
, 2
P
L
Document Number: 34071
3 -
, 3
Revision: 10-Aug-06
Volts Output
P
L
3 -
5
4
4

Related parts for PL110800CC

PL110800CC Summary of contents

Page 1

... PL-11, PL-12, PL-13, PL-14, PL-32, PL-33, PL-34 Vishay Dale Low Power Transformers Single Primary, Input 115 V Dual Secondary: PL-11 thru PL-14, Single Secondary: PL-32 thru PL-34 ELECTRICAL SPECIFICATIONS Input Voltage: 115 Output Power Rating: PL-11 = 0.75 VA PL-12, PL-32 = 1.50 VA PL-13, PL-33 = 4.50 VA PL-14, PL- ...

Page 2

... For technical questions, contact: magnetics@vishay.com Vishay Dale SINGLE SECONDARY OUTPUT OUTPUT MODEL CURRENT VOLTAGE (mA) PL-32-01 200 PL-33-01 6.4 V 700 PL-34-01 1300 PL-32-02 120 PL-33- 450 PL-34-02 800 PL-32-03 100 PL-33-03 12.6 V 350 PL-34-03 650 ...

Page 3

... PL-11, PL-12, PL-13, PL-14, PL-32, PL-33, PL-34 Vishay Dale DIMENSIONAL CONFIGURATIONS (Reference) in inches (millimeters) Basic Style B 0.041 0.150 (1.04) (3.81) C Typ. Min. “A” Type of Mounting Frame “B” Type of Mounting Frame MODEL 1.04 0.860 0.250 PL-11 (26.42) (21.84) (6.35) PL-12 1 ...

Page 4

... Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part ...

Related keywords